摘要:Intraoperative Gamma Probe (IPG) remains the current gold standard modality for sentinel lymph node identification and tumor removal in cancer patients. However, even alongside the optical dyes they do not meet with <5% false negative rates (FNR) requirement, a key metric suggested by the American Society of Clinical Oncology (ASCO). We are aiming to reduce FNR by using time of flight (TOF) PET detector technology in the limited angle geometry system by using only two detector buckets in coincidence, where one small-area detector is placed above the patient and the other with larger detection-area, placed just under the patient bed. For proof of concept, we used two Hamamatsu TOF PET detector modules (C13500-4075YC-12) featuring 12x12 array of 4.2x4.2x20 mm3 LFS crystal pixels, one-one coupled to silicon photomultiplier (SiPM) pixels. Detector coincidence timing resolution (CTR) measured 271 ps FWHM for the whole detector. We 3D printed lesion phantom containing spheres with 2-10 mm in diameter, representing lymph nodes, and placed it inside a 10-liter warm background water phantom. Experimental results show that with sub-minute data acquisition, 6 mm diameter spheres can be identified in the image when a lesion phantom with 10:1 activity ratio to background is used. Simulation results are in good agreement with the experimental data, by resolving 6 mm diameters lesions with 60 seconds acquisition time, in 25 cm deep background water phantom with 10:1 activity ratio. The image quality improves as the CTR improves in the simulation, and with decreasing background water phantom depth or lesion to background activity ratio, in the experiment. With the results presented here we conclude that limited angle TOF PET detector is a major step forward for intraoperative applications in that, improved lesion detectability is beyond what the conventional Gamma- and NIR-based probes could achieve.
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2104.03257 [physics.med-ph]
  (或者 arXiv:2104.03257v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2104.03257
相关 DOI: https://doi.org/10.1088/1748-0221/17/01/T01002

提交历史

来自:Hamid Sabet
[v1] 2022年1月26日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2022-01
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站