标题:Highly Accelerated EPI with Wave Encoding and Multi-shot Simultaneous Multi-Slice Imaging

作者:Jaejin Cho, Congyu Liao, Qiyuan Tian, Zijing Zhang, Jinmin Xu, Wei-Ching Lo, Benedikt A. Poser, V. Andrew Stenger, Jason Stockmann, Kawin Setsompop, Berkin Bilgic
查看论文《Highly Accelerated EPI with Wave Encoding and Multi-shot Simultaneous Multi-Slice Imaging》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:We introduce wave encoded acquisition and reconstruction techniques for highly accelerated echo planar imaging (EPI) with reduced g-factor penalty and image artifacts. Wave-EPI involves playing sinusoidal gradients during the EPI readout while employing interslice shifts as in blipped-CAIPI acquisitions. This spreads the aliasing in all spatial directions, thereby taking better advantage of 3D coil sensitivity profiles. The amount of voxel spreading that can be achieved by the wave gradients during the short EPI readout period is constrained by the slew rate of the gradient coils and peripheral nerve stimulation (PNS) monitor. We propose to use a half-cycle sinusoidal gradient to increase the amount of voxel spreading that can be achieved while respecting the slew and stimulation constraints. Extending wave-EPI to multi-shot acquisition minimizes geometric distortion and voxel blurring at high in-plane resolution, while structured low-rank regularization mitigates shot-to-shot phase variations without additional navigators. We propose to use different point spread functions (PSFs) for the k-space lines with positive and negative polarities, which are calibrated with a FLEET-based reference scan and allow for addressing gradient imperfections. Wave-EPI provided whole-brain single-shot gradient echo (GE) and multi-shot spin echo (SE) EPI acquisitions at high acceleration factors and was combined with g-Slider slab encoding to boost the SNR level in 1mm isotropic diffusion imaging. Relative to blipped-CAIPI, wave-EPI reduced average and maximum g-factors by up to 1.21- and 1.37-fold, respectively. In conclusion, wave-EPI allows highly accelerated single- and multi-shot EPI with reduced g-factor and artifacts and may facilitate clinical and neuroscientific applications of EPI by improving the spatial and temporal resolution in functional and diffusion imaging.
主题: 图像与视频处理 (eess.IV); 信号处理 (eess.SP); 生物物理 (physics.bio-ph)
引用方式: arXiv:2106.01918 [eess.IV]
  (或者 arXiv:2106.01918v1 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.2106.01918

提交历史

来自:Jaejin Cho
[v1] 2021年6月4日 星期五 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2021-06
切换浏览方式为:
eess
eess.SP
physics.bio-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站