标题:The influence of nuclear models and Monte Carlo radiation transport codes on stray neutron dose estimations in proton therapy

作者:M. De Saint-Hubert, J. Farah, M. Klodowska, M. T. Romero-Exposito, K. Tyminska, V. Mares, P. Olko, L Stolarczyk, S. Trinkl
查看论文《The influence of nuclear models and Monte Carlo radiation transport codes on stray neutron dose estimations in proton therapy》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:This study investigates the influence of several Monte Carlo radiation transport codes and nuclear models on the simulation of secondary neutron spectra and its impact on calculating and measuring neutron doses in proton therapy. Three different multi-purpose Monte Carlo radiation transport codes (FLUKA, MCNPX, Geant4) were used with different available nuclear models to calculate secondary neutron energy spectra at various points inside a water tank phantom with PMMA walls using a 10 cm x 10 cm rectangular, mono-energetic proton beam (110, 150, 180, and 210 MeV). Using Kerma approximation secondary neutron doses were calculated applying fluence-to-dose equivalent conversion coefficients in water. Moreover, the impact of varying spectra for electrochemically etched CR39 detector calibration was analyzed for different codes and models. In distal positions beyond the Bragg peak, results show largest variations between the codes, up to 53% for the high energy neutron fluence at 16 cm from the Bragg peak of the 110 MeV proton beam. In lateral positions, the variation between the codes is smaller and for the total neutron fluence within 20%. Variation in the nuclear models in MCNPX was only visible for the proton beam energies of 180 and 210 MeV and modeling the high energy neutron fluence which reached up to 23% for 210 MeV at 11 cm lateral from the beam axis. Impact on neutron dose equivalent was limited for the different models used (<8%) while it was pronounced for the different codes (45% at 16 cm from the Bragg peak of the 110 MeV proton beam). CR39 calibration factors in lateral positions were on average varying 10% between codes and 5 % between nuclear models.This study demonstrated a large impact on the neutron fluence spectra calculated by different codes while the impact of different models in MCNPX proved to be less prominent for the neutron modeling in proton therapy.
评论: 30 pages, 4 figures, 8 tables, accepted for publication in Radiation Measurements
主题: 医学物理 (physics.med-ph); 计算物理 (physics.comp-ph)
引用方式: arXiv:2112.03880 [physics.med-ph]
  (或者 arXiv:2112.03880v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2112.03880
期刊参考: Radiation Measurements 150 (2022) 106693
相关 DOI: https://doi.org/10.1016/j.radmeas.2021.106693

提交历史

来自:Marijke de Saint-Hubert
[v1] 2022年1月5日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2022-01
切换浏览方式为:
physics
physics.comp-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站