跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 信号处理

arXiv:2202.00606 (eess)
[提交于 2022年10月11日]

标题:Signal Quality Assessment of Photoplethysmogram Signals using Quantum Pattern Recognition and lightweight CNN Architecture

作者:Tamaghno Chatterjee, Aayushman Ghosh, Sayan Sarkar
查看论文《Signal Quality Assessment of Photoplethysmogram Signals using Quantum Pattern Recognition and lightweight CNN Architecture》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Photoplethysmography (PPG) signal comprises physiological information related to cardiorespiratory health. However, while recording, these PPG signals are easily corrupted by motion artifacts and body movements, leading to noise enriched, poor quality signals. Therefore ensuring high-quality signals is necessary to extract cardiorespiratory information accurately. Although there exists several rule-based and Machine-Learning (ML) - based approaches for PPG signal quality estimation, those algorithms' efficacy is questionable. Thus, this work proposes a lightweight CNN architecture for signal quality assessment employing a novel Quantum pattern recognition (QPR) technique. The proposed algorithm is validated on manually annotated data obtained from the University of Queensland database. A total of 28366, 5s signal segments are preprocessed and transformed into image files of 20 x 500 pixels. The image files are treated as an input to the 2D CNN architecture. The developed model classifies the PPG signal as `good' or `bad' with an accuracy of 98.3% with 99.3% sensitivity, 94.5% specificity and 98.9% F1-score. Finally, the performance of the proposed framework is validated against the noisy `Welltory app' collected PPG database. Even in a noisy environment, the proposed architecture proved its competence. Experimental analysis concludes that a slim architecture along with a novel Spatio-temporal pattern recognition technique improve the system's performance. Hence, the proposed approach can be useful to classify good and bad PPG signals for a resource-constrained wearable implementation.
评论: 7 pages, 6 figures, submitted to IEEE EMBC 2022
主题: 信号处理 (eess.SP); 机器学习 (cs.LG)
引用方式: arXiv:2202.00606 [eess.SP]
  (或者 arXiv:2202.00606v1 [eess.SP] 对于此版本)
  https://doi.org/10.48550/arXiv.2202.00606
相关 DOI: https://doi.org/10.1109/EMBC48229.2022.9871494

提交历史

来自:Aayushman Ghosh
[v1] 2022年10月11日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SP
< 上一篇   |   下一篇 >
最新 | 近期 | 2022-10
切换浏览方式为:
eess
cs.LG

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站