跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 核实验

arXiv:2204.06655 (nucl-ex)
[提交于 2022年4月13日]

标题:Performance of a convolutional autoencoder designed to remove electronic noise from p-type point contact germanium detector signals

作者:Mark R. Anderson, Vasundhara Basu, Ryan D. Martin, Charlotte Z. Reed, Noah J. Rowe, Mehdi Shafiee, Tianai Ye
查看论文《Performance of a convolutional autoencoder designed to remove electronic noise from p-type point contact germanium detector signals》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:We present a convolutional autoencoder to denoise pulses from a p-type point contact high-purity germanium detector similar to those used in several rare event searches. While we focus on training procedures that rely on detailed detector physics simulations, we also present implementations requiring only noisy detector pulses to train the model. We validate our autoencoder on both simulated data and calibration data from an $^{241}$Am source, the latter of which is used to show that the denoised pulses are statistically compatible with data pulses. We demonstrate that our denoising method is able to preserve the underlying shapes of the pulses well, offering improvement over traditional denoising methods. We also show that the shaping time used to calculate energy with a trapezoidal filter can be significantly reduced while maintaining a comparable energy resolution. Under certain circumstances, our denoising method can improve the overall energy resolution. The methods we developed to remove electronic noise are straightforward to extend to other detector technologies. Furthermore, the latent representation from the encoder is also of use in quantifying shape-based characteristics of the signals. Our work has great potential to be used in particle physics experiments and beyond.
评论: 21 pages, 13 figures, 3 tables. This version of the article has been accepted for publication, after peer review but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: 10.1140/epjc/s10052-022-11000-w
主题: 核实验 (nucl-ex); 数据分析、统计与概率 (physics.data-an); 仪器与探测器 (physics.ins-det)
引用方式: arXiv:2204.06655 [nucl-ex]
  (或者 arXiv:2204.06655v1 [nucl-ex] 对于此版本)
  https://doi.org/10.48550/arXiv.2204.06655
期刊参考: Eur. Phys. J. C 82, 1084 (2022)
相关 DOI: https://doi.org/10.1140/epjc/s10052-022-11000-w

提交历史

来自:Mark Russell Anderson
[v1] 2022年4月13日 星期三 22:27:56 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

nucl-ex
< 上一篇   |   下一篇 >
最新 | 近期 | 2022-04
切换浏览方式为:
physics.data-an
physics.ins-det

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站