跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 图像与视频处理

arXiv:2205.04094 (eess)
[提交于 2024年4月18日]

标题:Robust phase retrieval with complexity-guidance for coherent X-ray imaging

作者:Mansi Butola, Sunaina Rajora, Kedar Khare
查看论文《Robust phase retrieval with complexity-guidance for coherent X-ray imaging》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Reconstruction of a stable and reliable solution from noisy incomplete Fourier intensity data recorded in a coherent X-ray imaging (CXI) experiment is a challenging problem. The Relaxed Averaged Alternating Reflections (RAAR) algorithm that is concluded with a number of Error Reduction (ER) iterations is a popular choice. The RAAR-ER algorithm is usually employed for several hundreds of times starting with independent random guesses to obtain trial solutions that are then averaged to obtain the phase retrieval transfer function (PRTF). In this paper, we examine the phase retrieval solution obtained using the RAAR-ER methodology from perspective of the complexity parameter that was introduced by us in recent works. We observe that a single run of the RAAR-ER algorithm produces a solution with higher complexity compared to what is expected based on the complexity parameter as manifested by spurious high frequency grainy artifacts in the solution that do not seem to go away completely even after a number of trial solutions are averaged. We then describe a CG-RAAR (Complexity Guided RAAR) phase retrieval method that can effectively address this inconsistency problem and provides artifact-free solutions. The CG-RAAR methodology is first illustrated with simulated unblocked noisy Fourier intensity data and later applied to centrally-blocked noisy cyanobacterium data which is available from the CXIDB database. Our simulation and experimental results using CG-RAAR suggest two important improvements over the popular RAAR-ER algorithm. The CG-RAAR solutions after the averaging procedure is more reliable in the sense that it contains smallest features consistent with the resolution estimated by the PRTF curve. Secondly, since the single run of the CG-RAAR solution does not have grainy artifacts, the number of trial solutions needed for the averaging process is reduced.
主题: 图像与视频处理 (eess.IV); 医学物理 (physics.med-ph)
引用方式: arXiv:2205.04094 [eess.IV]
  (或者 arXiv:2205.04094v1 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.2205.04094
期刊参考: Intell. Comput. 2022, 9819716 (2022)
相关 DOI: https://doi.org/10.34133/2022/9819716

提交历史

来自:Kedar Khare
[v1] 2024年4月18日 星期四 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-04
切换浏览方式为:
eess
physics.med-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站