计算机科学 > 分布式、并行与集群计算
[提交于 2022年5月12日]
标题:Optimizing Apportionment of Redundancies in Hierarchical RAID
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:Large disk arrays are organized into storage nodes -- SNs or bricks with their own cashed RAID controller for multiple disks. Erasure coding at SN level is attained via parity or Reed-Solomon codes. Hierarchical RAID -- HRAID -- provides an additional level of coding across SNs, e.g., check strips P, Q at intra-SN level and R at the inter-SN level. Failed disks and SNs are not replaced and rebuild is accomplished by restriping, e.g., overwriting P and Q for disk failures and R for an SN failure. For a given total redundancy level we use an approximate reliability analysis method and Monte-Carlo simulation to explore the better apportionment of check blocks for intra- vs inter-SN redundancy. Our study indicates that a higher MTTDL -- Mean-Time-to-Data-Loss -- is attained by associating higher reliability at intra-SN level rather than inter-SN level, which is contrary to that of an IBM study.
提交历史
来自:Alexander Thomasian[v1] 2022年5月12日 星期四 19:44:11 UTC