跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 仪器与探测器

arXiv:2205.15042 (physics)
[提交于 2022年7月5日]

标题:Interpretation of field emission current-voltage data: background theory and detailed simulation testing of a user-friendly webtool

作者:Mohammad M. Allaham, Richard G. Forbes, Alexandr Knapek, Dinara Sobola, Daniel Burdaa, Petr Sedlak, Marwan S. Mousa
查看论文《Interpretation of field emission current-voltage data: background theory and detailed simulation testing of a user-friendly webtool》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:In field electron emission (FE) studies, to interpret current-voltage data and extract characterization parameters, we use smooth planar metal-like emitter (SPME) methodology and a data-analysis plot. Three types exist: Millikan-Lauritsen (ML), Fowler-Nordheim (FN) and Murphy-Good (MG) plots. In SPME methodology, ML and FN plots are slightly curved but a MG plot is nearly straight. 1956 MG FE theory is better physics than 1928 FN theory, so we expect MG plots to be more precise than ML or FN plots. Current-voltage data are often converted: measured voltage to (apparent) macroscopic field, current to macroscopic current density. Thus, four different data-input forms exist. Over-simplified models of system behaviour are widely assumed. Whether simple use of a data-analysis plot is a valid interpretation method is often neglected. Published FE studies seem to contain a high incidence of spurious values for "field enhancement factor". A procedure (the "Orthodoxy Test") described in 2013 allows a validity check: around 40 % of a small sample of results were spuriously high. To assist data interpretation and validity checks, a simple user-friendly webtool has been designed by the lead author. As inputs, this needs system specification data and "range-limits" data from any of the three plot forms, using any of the four data-input forms. The webtool then applies the Orthodoxy Test, and -- if passed -- extracts characterization parameters. This study reports: (1) systematic tests of webtool functionality, using simulated input data prepared using Extended MG FE theory; and (2) systematic comparisons of the three different data-plot types, to check how well extracted parameter values match simulation input values. A summary review of relevant theory is given. For formal emission areas, the MG plot performs better than FN and ML plots. This is important for FE science.
评论: 16 printed pages, 8 figures. Open-access published version
主题: 仪器与探测器 (physics.ins-det); 应用物理 (physics.app-ph)
引用方式: arXiv:2205.15042 [physics.ins-det]
  (或者 arXiv:2205.15042v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.2205.15042
期刊参考: Mater. Today Commun. 31, 103654 (2022)
相关 DOI: https://doi.org/10.1016/j.mtcomm.2022.103654

提交历史

来自:Richard Forbes
[v1] 2022年7月5日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2022-07
切换浏览方式为:
physics
physics.app-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站