跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 仪器与探测器

arXiv:2208.05054 (physics)
[提交于 2024年4月4日]

标题:Alignment of the CLAS12 central hybrid tracker with a Kalman Filter

作者:S. J. Paul, A. Peck, M. Arratia, Y. Gotra, V. Ziegler, R. De Vita, F. Bossu, M. Defurne, H. Atac, C. Ayerbe Gayoso, L. Baashen, N. A. Baltzell, L. Barion, M. Bashkanov, M. Battaglieri, I. Bedlinskiy, B. Benkel, F. Benmokhtar, A. Bianconi, L. Biondo, A. S. Biselli, M. Bondi, S. Boiarinov, K. Th. Brinkmann, W. J. Briscoe, W. K. Brooks, D. Bulumulla, V. D. Burkert, R. Capobianco, D. S. Carman, J. C. Carvajal, P. Chatagnon, V. Chesnokov, T. Chetry, G. Ciullo, P. L. Cole, G. Costantini, A. D Angelo, N. Dashyan, A. Deur, S. Diehl, C. Djalali, R. Dupre, A. El Alaoui, L. El Fassi, L. Elouadrhiri, A. Filippi, K. Gates, G. Gavalian, Y. Ghandilyan, G. P. Gilfoyle, A. A. Golubenko, G. Gosta, R. W. Gothe, K. Griffioen, M. Guidal, H. Hakobyan, M. Hattawy, F. Hauenstein, T. B. Hayward, D. Heddle, A. Hobart, M. Holtrop, Y. Ilieva, D. G. Ireland, E. L. Isupov, H. S. Jo, R. Johnston, K. Joo, D. Keller, M. Khachatryan, A. Khanal, A. Kim, W. Kim, V. Klimenko, A. Kripko, L. Lanza, M. Leali, P. Lenisa, X. Li, I. J. D. MacGregor, D. Marchand, L. Marsicano, V. Mascagna, B. McKinnon, C. McLauchlin, S. Migliorati, T. Mineeva, M. Mirazita, V. Mokeev, C. Munoz Camacho, P. Nadel-Turonski, P. Naidoo, K. Neupane, D. Nguyen, S. Niccolai, M. Nicol, G. Niculescu, M. Osipenko, P. Pandey, M. Paolone, R. Paremuzyan, N. Pilleux, O. Pogorelko, M. Pokhrel, J. Poudel, J. W. Price, Y. Prok, T. Reed, M. Ripani, J. Ritman, F. Sabatie, S. Schadmand, A. Schmidt, E. V. Shirokov, U. Shrestha, P. Simmerling, M. Spreafico, D. Sokhan, N. Sparveris, I. I. Strakovsky, S. Strauch, J. A. Tan, R. Tyson, M. Ungaro, S. Vallarino, L. Venturelli, H. Voskanyan, E. Voutier, D. P. Watts, X. Wei, R. Wishart, M. H. Wood, N. Zachariou
查看论文《Alignment of the CLAS12 central hybrid tracker with a Kalman Filter》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5~T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10~$\mu$m, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.
主题: 仪器与探测器 (physics.ins-det); 高能物理 - 实验 (hep-ex); 核实验 (nucl-ex)
引用方式: arXiv:2208.05054 [physics.ins-det]
  (或者 arXiv:2208.05054v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.2208.05054
期刊参考: Nucl.Instrum.Meth.A 1049 (2023) 168032
相关 DOI: https://doi.org/10.1016/j.nima.2023.168032

提交历史

来自:Miguel Arratia
[v1] 2024年4月4日 星期四 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-04
切换浏览方式为:
physics
hep-ex
nucl-ex

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站