标题:Accelerated partial separable model using dimension-reduced optimization technique for ultra-fast cardiac MRI

作者:Zhongsen Li, Aiqi Sun, Chuyu Liu, Haining Wei, Shuai Wang, Mingzhu Fu, Rui Li
查看论文《Accelerated partial separable model using dimension-reduced optimization technique for ultra-fast cardiac MRI》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objective. Imaging dynamic object with high temporal resolution is challenging in magnetic resonance imaging (MRI). Partial separable (PS) model was proposed to improve the imaging quality by reducing the degrees of freedom of the inverse problem. However, PS model still suffers from long acquisition time and even longer reconstruction time. The main objective of this study is to accelerate the PS model, shorten the time required for acquisition and reconstruction, and maintain good image quality simultaneously. Approach. We proposed to fully exploit the dimension reduction property of the PS model, which means implementing the optimization algorithm in subspace. We optimized the data consistency term, and used a Tikhonov regularization term based on the Frobenius norm of temporal difference. The proposed dimension-reduced optimization technique was validated in free-running cardiac MRI. We have performed both retrospective experiments on public dataset and prospective experiments on in-vivo data. The proposed method was compared with four competing algorithms based on PS model, and two non-PS model methods. Main results. The proposed method has robust performance against shortened acquisition time or suboptimal hyper-parameter settings, and achieves superior image quality over all other competing algorithms. The proposed method is 20-fold faster than the widely accepted PS+Sparse method, enabling image reconstruction to be finished in just a few seconds. Significance. Accelerated PS model has the potential to save much time for clinical dynamic MRI examination, and is promising for real-time MRI applications.
评论: 23 pages, 11 figures. Accepted as manuscript on Physics in Medicine & Biology
主题: 图像与视频处理 (eess.IV); 信号处理 (eess.SP)
引用方式: arXiv:2210.00493 [eess.IV]
  (或者 arXiv:2210.00493v1 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.2210.00493
相关 DOI: https://doi.org/10.1088/1361-6560/acc9a1

提交历史

来自:Zhongsen Li
[v1] 2023年5月24日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2023-05
切换浏览方式为:
eess
eess.SP

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站