电气工程与系统科学 > 信号处理

arXiv:2301.01469 (eess)
[提交于 2023年1月5日]

标题:Machine Learning-based Signal Quality Assessment for Cardiac Volume Monitoring in Electrical Impedance Tomography

作者:Chang Min Hyun, Tae Jun Jang, Jeongchan Nam, Hyeuknam Kwon, Kiwan Jeon, Kyunghun Lee
查看论文《Machine Learning-based Signal Quality Assessment for Cardiac Volume Monitoring in Electrical Impedance Tomography》的 PDF
查看中文 PDF 查看原文 PDF EasyResearch 阅读
摘要:Owing to recent advances in thoracic electrical impedance tomography, a patient's hemodynamic function can be noninvasively and continuously estimated in real-time by surveilling a cardiac volume signal associated with stroke volume and cardiac output. In clinical applications, however, a cardiac volume signal is often of low quality, mainly because of the patient's deliberate movements or inevitable motions during clinical interventions. This study aims to develop a signal quality indexing method that assesses the influence of motion artifacts on transient cardiac volume signals. The assessment is performed on each cardiac cycle to take advantage of the periodicity and regularity in cardiac volume changes. Time intervals are identified using the synchronized electrocardiography system. We apply divergent machine-learning methods, which can be sorted into discriminative-model and manifold-learning approaches. The use of machine-learning could be suitable for our real-time monitoring application that requires fast inference and automation as well as high accuracy. In the clinical environment, the proposed method can be utilized to provide immediate warnings so that clinicians can minimize confusion regarding patients' conditions, reduce clinical resource utilization, and improve the confidence level of the monitoring system. Numerous experiments using actual EIT data validate the capability of cardiac volume signals degraded by motion artifacts to be accurately and automatically assessed in real-time by machine learning. The best model achieved an accuracy of 0.95, positive and negative predictive values of 0.96 and 0.86, sensitivity of 0.98, specificity of 0.77, and AUC of 0.96.
主题: 信号处理 (eess.SP); 机器学习 (cs.LG); 医学物理 (physics.med-ph)
引用方式: arXiv:2301.01469 [eess.SP]
  (或者 arXiv:2301.01469v1 [eess.SP] 对于此版本)
  https://doi.org/10.48550/arXiv.2301.01469

提交历史

来自:Chang Min Hyun
[v1] 2023年1月5日 星期四 00:00:00 UTC
全文链接:

访问论文:

  • 查看中文 PDF
  • 查看原文 PDF
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SP
< 上一篇   |   下一篇 >
最新 | 近期 | 2023-01
切换浏览方式为:
eess
cs.LG
physics.med-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站