标题:Attention-based Saliency Maps Improve Interpretability of Pneumothorax Classification

作者:Alessandro Wollek, Robert Graf, Saša Čečatka, Nicola Fink, Theresa Willem, Bastian O. Sabel, Tobias Lasser
查看论文《Attention-based Saliency Maps Improve Interpretability of Pneumothorax Classification》的 PDF
查看中文 PDF 查看原文 PDF EasyResearch 阅读
摘要:Purpose: To investigate chest radiograph (CXR) classification performance of vision transformers (ViT) and interpretability of attention-based saliency using the example of pneumothorax classification. Materials and Methods: In this retrospective study, ViTs were fine-tuned for lung disease classification using four public data sets: CheXpert, Chest X-Ray 14, MIMIC CXR, and VinBigData. Saliency maps were generated using transformer multimodal explainability and gradient-weighted class activation mapping (GradCAM). Classification performance was evaluated on the Chest X-Ray 14, VinBigData, and SIIM-ACR data sets using the area under the receiver operating characteristic curve analysis (AUC) and compared with convolutional neural networks (CNNs). The explainability methods were evaluated with positive/negative perturbation, sensitivity-n, effective heat ratio, intra-architecture repeatability and interarchitecture reproducibility. In the user study, three radiologists classified 160 CXRs with/without saliency maps for pneumothorax and rated their usefulness. Results: ViTs had comparable CXR classification AUCs compared with state-of-the-art CNNs 0.95 (95% CI: 0.943, 0.950) versus 0.83 (95%, CI 0.826, 0.842) on Chest X-Ray 14, 0.84 (95% CI: 0.769, 0.912) versus 0.83 (95% CI: 0.760, 0.895) on VinBigData, and 0.85 (95% CI: 0.847, 0.861) versus 0.87 (95% CI: 0.868, 0.882) on SIIM ACR. Both saliency map methods unveiled a strong bias toward pneumothorax tubes in the models. Radiologists found 47% of the attention-based saliency maps useful and 39% of GradCAM. The attention-based methods outperformed GradCAM on all metrics. Conclusion: ViTs performed similarly to CNNs in CXR classification, and their attention-based saliency maps were more useful to radiologists and outperformed GradCAM.
主题: 图像与视频处理 (eess.IV); 计算机视觉与模式识别 (cs.CV)
引用方式: arXiv:2303.01871 [eess.IV]
  (或者 arXiv:2303.01871v1 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.2303.01871
相关 DOI: https://doi.org/10.1148/ryai.220187

提交历史

来自:Alessandro Wollek
[v1] 2023年5月9日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看中文 PDF
  • 查看原文 PDF
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2023-05
切换浏览方式为:
eess
cs.CV

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站