标题:Active Personal Eye Lens Dosimetry with the Hybrid Pixelated Dosepix Detector

作者:Florian Beißer, Dennis Haag, Rafael Ballabriga, Rolf Behrens, Michael Campbell, Christian Fuhg, Patrick Hufschmidt, Oliver Hupe, Carolin Kupillas, Xavier Llopart, Jürgen Roth, Sebastian Schmidt, Markus Schneider, Lukas Tlustos, Winnie Wong, Hayo Zutz, Thilo Michel, Erlangen Centre for Astroparticle Physics, CERN, Physikalisch-Technische Bundesantalt, was with the Erlangen Centre for Astroparticle Physics, is now with Helene-Lange-Gymnasium, was with the Erlangen Centre for Astroparticle Physics, is now with CodeCamp, :, N GmbH, Institute of Experimental, Applied Physics, Czech Technical University, was with CERN, is now with Mercury Systems
查看论文《Active Personal Eye Lens Dosimetry with the Hybrid Pixelated Dosepix Detector》的 PDF
查看中文 PDF 查看原文 PDF EasyResearch 阅读
摘要:Eye lens dosimetry has been an important field of research in the last decade. Dose measurements with a prototype of an active personal eye lens dosemeter based on the Dosepix detector are presented. The personal dose equivalent at $3\,$mm depth of soft tissue, $H_\text{p}(3)$, was measured in the center front of a water-filled cylinder phantom with a height and diameter of $20\,$cm. The energy dependence of the normalized response is investigated for mean photon energies between $12.4\,$keV and $248\,$keV for continuous reference radiation fields (N-series) according to ISO 4037. The response normalized to N-60 ($\overline{E}=47.9\,\text{keV}$) at $0^\circ$ angle of irradiation stays within the approval limits of IEC 61526 for angles of incidence between $-75^\circ$ and $+75^\circ$. Performance in pulsed photon fields was tested for varying dose rates from $0.1\,\frac{\text{Sv}}{\text{h}}$ up to $1000\,\frac{\text{Sv}}{\text{h}}$ and pulse durations from $1\,\text{ms}$ up to $10\,\text{s}$. The dose measurement works well within the approval limits (acc. to IEC 61526) up to $1\,\frac{\text{Sv}}{\text{h}}$. No significant influence of the pulse duration on the measured dose is found. Reproducibility measurements yield a coefficient of variation which does not exceed $1\,\%$ for two tested eye lens dosemeter prototypes.
评论: This work has been submitted to the IEEE for possible publication. 9 pages, 10 figures
主题: 医学物理 (physics.med-ph); 仪器与探测器 (physics.ins-det)
引用方式: arXiv:2305.05470 [physics.med-ph]
  (或者 arXiv:2305.05470v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2305.05470

提交历史

来自:Florian Beißer
[v1] 2024年10月28日 星期一 00:00:00 UTC
全文链接:

访问论文:

  • 查看中文 PDF
  • 查看原文 PDF
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-10
切换浏览方式为:
physics
physics.ins-det

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站