物理学 > 仪器与探测器
[提交于 2023年8月8日]
标题:Open-access microcavities: high stability without dedicated mechanical low-pass filter in closed-cycle cryostats
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:Open-access optical microcavities are Fabry-Perot type cavities consisting of two micrometer-size mirrors, separated by an air (or vacuum) gap typically of a few micrometers. Compared to integrated microcavities, this configuration is more flexible as the relative position of the two mirrors can be tuned, allowing to change on demand parameters such as cavity length and mode volume, and to select specific transverse cavity modes. These advantages come at the expense of mechanical stability of the cavity itself, which is particularly relevant in noisy closed-cycle cryostats. Here we show an open-access optical microcavity based on scanning-probe microscope design principles. When operated at 4 K in a tabletop optical closed-cycle cryostat without any dedicated low-pass filter, we obtain stabilities of 5.7 and 10.6 pm rms in the quiet and full period of the cryocooler cycle, respectively. Our device has free-space optical access, essential for instance for full polarization control.
提交历史
来自:Matteo Fisicaro[v1] 2023年8月8日 星期二 00:00:00 UTC
当前浏览上下文:
physics.ins-det
切换浏览方式为: