跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:2309.00590 (physics)
[提交于 2024年4月11日]

标题:Neural blind deconvolution for deblurring and supersampling PSMA PET

作者:Caleb Sample, Arman Rahmim, Carlos Uribe, François Bénard, Jonn Wu, Roberto Fedrigo, Haley Clark
查看论文《Neural blind deconvolution for deblurring and supersampling PSMA PET》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objective: To simultaneously deblur and supersample prostate specific membrane antigen (PSMA) positron emission tomography (PET) images using neural blind deconvolution. Approach: Blind deconvolution is a method of estimating the hypothetical "deblurred" image along with the blur kernel (related to the point spread function) simultaneously. Traditional \textit{maximum a posteriori} blind deconvolution methods require stringent assumptions and suffer from convergence to a trivial solution. A method of modelling the deblurred image and kernel with independent neural networks, called "neural blind deconvolution" had demonstrated success for deblurring 2D natural images in 2020. In this work, we adapt neural blind deconvolution for PVE correction of PSMA PET images with simultaneous supersampling. We compare this methodology with several interpolation methods, using blind image quality metrics, and test the model's ability to predict kernels by re-running the model after applying artificial "pseudokernels" to deblurred images. The methodology was tested on a retrospective set of 30 prostate patients as well as phantom images containing spherical lesions of various volumes. Results: Neural blind deconvolution led to improvements in image quality over other interpolation methods in terms of blind image quality metrics, recovery coefficients, and visual assessment. Predicted kernels were similar between patients, and the model accurately predicted several artificially-applied pseudokernels. Localization of activity in phantom spheres was improved after deblurring, allowing small lesions to be more accurately defined. Significance: The intrinsically low spatial resolution of PSMA PET leads to PVEs which negatively impact uptake quantification in small regions. The proposed method can be used to mitigate this issue, and can be straightforwardly adapted for other imaging modalities.
评论: 10 Figures, 4 Tables, 19 pages
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2309.00590 [physics.med-ph]
  (或者 arXiv:2309.00590v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2309.00590
相关 DOI: https://doi.org/10.1088/1361-6560/ad36a9

提交历史

来自:Caleb Sample
[v1] 2024年4月11日 星期四 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-04
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站