标题:Step length measurement in the wild using FMCW radar

作者:Parthipan Siva, Alexander Wong, Patricia Hewston, George Ioannidis, Jonathan Adachi, Alexander Rabinovich, Andrea Lee, Alexandra Papaioannou
查看论文《Step length measurement in the wild using FMCW radar》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:With an aging population, numerous assistive and monitoring technologies are under development to enable older adults to age in place. To facilitate aging in place predicting risk factors such as falls, and hospitalization and providing early interventions are important. Much of the work on ambient monitoring for risk prediction has centered on gait speed analysis, utilizing privacy-preserving sensors like radar. Despite compelling evidence that monitoring step length, in addition to gait speed, is crucial for predicting risk, radar-based methods have not explored step length measurement in the home. Furthermore, laboratory experiments on step length measurement using radars are limited to proof of concept studies with few healthy subjects. To address this gap, a radar-based step length measurement system for the home is proposed based on detection and tracking using radar point cloud, followed by Doppler speed profiling of the torso to obtain step lengths in the home. The proposed method was evaluated in a clinical environment, involving 35 frail older adults, to establish its validity. Additionally, the method was assessed in people's homes, with 21 frail older adults who had participated in the clinical assessment. The proposed radar-based step length measurement method was compared to the gold standard Zeno Walkway Gait Analysis System, revealing a 4.5cm/8.3% error in a clinical setting. Furthermore, it exhibited excellent reliability (ICC(2,k)=0.91, 95% CI 0.82 to 0.96) in uncontrolled home settings. The method also proved accurate in uncontrolled home settings, as indicated by a strong agreement (ICC(3,k)=0.81 (95% CI 0.53 to 0.92)) between home measurements and in-clinic assessments.
主题: 计算机视觉与模式识别 (cs.CV); 人工智能 (cs.AI)
引用方式: arXiv:2401.01868 [cs.CV]
  (或者 arXiv:2401.01868v1 [cs.CV] 对于此版本)
  https://doi.org/10.48550/arXiv.2401.01868

提交历史

来自:Parthipan Siva
[v1] 2024年8月31日 星期六 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.CV
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-08
切换浏览方式为:
cs
cs.AI

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站