标题:Exploring the limitations of blood pressure estimation using the photoplethysmography signal

作者:Felipe M. Dias, Diego A. C. Cardenas, Marcelo A. F. Toledo, Filipe A. C. Oliveira, Estela Ribeiro, Jose E. Krieger, Marco A. Gutierrez
查看论文《Exploring the limitations of blood pressure estimation using the photoplethysmography signal》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) presents a promising approach to this end. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, necessitating a comprehensive evaluation of their effectiveness and constraints. We developed a calibration-based Siamese ResNet model for BP estimation, using a signal input paired with a reference BP reading. We compared the use of normalized PPG (N-PPG) against the normalized Invasive Arterial Blood Pressure (N-IABP) signals as input. The N-IABP signals do not directly present systolic and diastolic values but theoretically provide a more accurate BP measure than PPG signals since it is a direct pressure sensor inside the body. Our strategy establishes a critical benchmark for PPG performance, realistically calibrating expectations for PPG's BP estimation capabilities. Nonetheless, we compared the performance of our models using different signal-filtering conditions to evaluate the impact of filtering on the results. We evaluated our method using the AAMI and the BHS standards employing the VitalDB dataset. The N-IABP signals meet with AAMI standards for both Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP), with errors of 1.29+-6.33mmHg for systolic pressure and 1.17+-5.78mmHg for systolic and diastolic pressure respectively for the raw N-IABP signal. In contrast, N-PPG signals, in their best setup, exhibited inferior performance than N-IABP, presenting 1.49+-11.82mmHg and 0.89+-7.27mmHg for systolic and diastolic pressure respectively. Our findings highlight the potential and limitations of employing PPG for BP estimation, showing that these signals contain information correlated to BP but may not be sufficient for predicting it accurately.
评论: 17 pages, 7 figures, 3 tables
主题: 医学物理 (physics.med-ph); 计算机视觉与模式识别 (cs.CV); 机器学习 (cs.LG); 图像与视频处理 (eess.IV); 信号处理 (eess.SP)
引用方式: arXiv:2404.16049 [physics.med-ph]
  (或者 arXiv:2404.16049v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2404.16049
相关 DOI: https://doi.org/10.1088/1361-6579/adcb86

提交历史

来自:Felipe Meneguitti Dias
[v1] 2025年4月22日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2025-04
切换浏览方式为:
physics
cs.CV
cs.LG
eess.IV
eess.SP

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站