标题:Implementing Bayesian inference on a stochastic CO2-based grey-box model for assessing indoor air quality in Canadian primary schools

作者:Shujie Yan, Jiwei Zou, Chang Shu, Justin Berquist, Vincent Brochu, Marc Veillette, Danlin Hou, Caroline Duchaine, Liang, Zhou, Zhiqiang, Zhai, Liangzhu, Wang
查看论文《Implementing Bayesian inference on a stochastic CO2-based grey-box model for assessing indoor air quality in Canadian primary schools》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The COVID-19 pandemic brought global attention to indoor air quality (IAQ), which is intrinsically linked to clean air change rates. Estimating the air change rate in indoor environments, however, remains challenging. It is primarily due to the uncertainties associated with the air change rate estimation, such as pollutant generation rates, dynamics including weather and occupancies, and the limitations of deterministic approaches to accommodate these factors. In this study, Bayesian inference was implemented on a stochastic CO2-based grey-box model to infer modeled parameters and quantify uncertainties. The accuracy and robustness of the ventilation rate and CO2 emission rate estimated by the model were confirmed with CO2 tracer gas experiments conducted in an airtight chamber. Both prior and posterior predictive checks (PPC) were performed to demonstrate the advantage of this approach. In addition, uncertainties in real-life contexts were quantified with an incremental variance {\sigma} for the Wiener process. This approach was later applied to evaluate the ventilation conditions within two primary school classrooms in Montreal. The Equivalent Clean Airflow Rate (ECAi) was calculated following ASHRAE 241, and an insufficient clean air supply within both classrooms was identified. A supplement of 800 cfm clear air delivery rate (CADR) from air-cleaning devices is recommended for a sufficient ECAi. Finally, steady-state CO2 thresholds (Climit, Ctarget, and Cideal) were carried out to indicate when ECAi requirements could be achieved under various mitigation strategies, such as portable air cleaners and in-room ultraviolet light, with CADR values ranging from 200 to 1000 cfm.
主题: 应用 (stat.AP)
引用方式: arXiv:2405.00582 [stat.AP]
  (或者 arXiv:2405.00582v1 [stat.AP] 对于此版本)
  https://doi.org/10.48550/arXiv.2405.00582

提交历史

来自:Shujie Yan
[v1] 2024年5月3日 星期五 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

stat.AP
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-05
切换浏览方式为:
stat

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站