跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 等离子体物理

arXiv:2406.07139 (physics)
[提交于 2024年6月11日]

标题:Increased accuracy and signal-to-noise ratio through recent improvements in Infra-Red Video Bolometer fabrication and calibration

作者:Fabio Federici, Jack J. Lovell, G. A. Wurden, Byron J. Peterson, Kiyofumi Mukai
查看论文《Increased accuracy and signal-to-noise ratio through recent improvements in Infra-Red Video Bolometer fabrication and calibration》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The Infra-Red Video Bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of LOSs within a large field of view (FOV). Recently validated in MAST-U, it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB's sensing element comprises a thin layer of high Z absorbing material, typically Platinum, usually coated with Carbon to reduce reflections. It is here explored the possibility of using a relatively inert material like Titanium, that can be produced in layers up to 1mum compared to 2.5mum for Pt, and then coat it with Pt of the desired thickness (0.3mum per side here) and Carbon. This leads to a higher temperature signal (2 to 3 times), and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes. Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analysing the temperature profile shape or fitting the calculated laser power for different intensities and frequencies. It is here presented a simpler approach, that relies on analysing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.
评论: Submitted to Review of Scientific Instruments
主题: 等离子体物理 (physics.plasm-ph); 仪器与探测器 (physics.ins-det)
引用方式: arXiv:2406.07139 [physics.plasm-ph]
  (或者 arXiv:2406.07139v1 [physics.plasm-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2406.07139
期刊参考: Rev. Sci. Instrum. 95, 103525 (2024)
相关 DOI: https://doi.org/10.1063/5.0219609

提交历史

来自:Fabio Federici
[v1] 2024年6月11日 星期二 10:37:36 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.plasm-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-06
切换浏览方式为:
physics
physics.ins-det

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站