跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 信号处理

arXiv:2407.03274 (eess)
[提交于 2024年7月4日]

标题:Using Photoplethysmography to Detect Real-time Blood Pressure Changes with a Calibration-free Deep Learning Model

作者:Jingyuan Hong, Manasi Nandi, Weiwei Jin, Jordi Alastruey
查看论文《Using Photoplethysmography to Detect Real-time Blood Pressure Changes with a Calibration-free Deep Learning Model》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Blood pressure (BP) changes are linked to individual health status in both clinical and non-clinical settings. This study developed a deep learning model to classify systolic (SBP), diastolic (DBP), and mean (MBP) BP changes using photoplethysmography (PPG) waveforms. Data from the Vital Signs Database (VitalDB) comprising 1,005 ICU patients with synchronized PPG and BP recordings was used. BP changes were categorized into three labels: Spike (increase above a threshold), Stable (change within a plus or minus threshold), and Dip (decrease below a threshold). Four time-series classification models were studied: multi-layer perceptron, convolutional neural network, residual network, and Encoder. A subset of 500 patients was randomly selected for training and validation, ensuring a uniform distribution across BP change labels. Two test datasets were compiled: Test-I (n=500) with a uniform distribution selection process, and Test-II (n=5) without. The study also explored the impact of including second-deviation PPG (sdPPG) waveforms as additional input information. The Encoder model with a Softmax weighting process using both PPG and sdPPG waveforms achieved the highest detection accuracy--exceeding 71.3% and 85.4% in Test-I and Test-II, respectively, with thresholds of 30 mmHg for SBP, 15 mmHg for DBP, and 20 mmHg for MBP. Corresponding F1-scores were over 71.8% and 88.5%. These findings confirm that PPG waveforms are effective for real-time monitoring of BP changes in ICU settings and suggest potential for broader applications.
评论: 8 pages, 5 figures, 7 tables, 1 supplementary material
主题: 信号处理 (eess.SP)
引用方式: arXiv:2407.03274 [eess.SP]
  (或者 arXiv:2407.03274v1 [eess.SP] 对于此版本)
  https://doi.org/10.48550/arXiv.2407.03274

提交历史

来自:Jingyuan Hong
[v1] 2024年7月4日 星期四 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SP
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-07
切换浏览方式为:
eess

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站