跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 数据分析、统计与概率

arXiv:2408.07991 (physics)
[提交于 2024年8月15日]

标题:Wavelength calibration and spectral sensitivity correction of luminescence measurements for dosimetry applications: method comparison tested on the IR-RF of K-feldspar

作者:Mariana Sontag-González, Dirk Mittelstraß, Sebastian Kreutzer, Markus Fuchs
查看论文《Wavelength calibration and spectral sensitivity correction of luminescence measurements for dosimetry applications: method comparison tested on the IR-RF of K-feldspar》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Spectroscopic investigations provide important insights into the composition of luminescence emissions relevant to trapped-charge dating of sediments. Accurate wavelength calibration and a correction for the wavelength-dependent detection efficiency of the spectrometer system are crucial to ensure the correct spectrum interpretation and allow for its comparison with those obtained from other systems. However, to achieve an accurate detection efficiency correction, it is necessary to obtain the device-specific spectral response function (SRF). Here, we compare two SRF approximation methods by using either a calibration lamp of known irradiance or calculating the product of efficiency curves provided by the manufacturers of all known optical elements. We discuss the results using radiofluorescence (RF) measurements of two K-feldspar samples as an example. Feldspar infra-red (IR) RF spectra are known to be composed of several overlapping emissions, whose variation with sample mineralogy is still poorly understood and requires more extensive investigations. We find that both methods of sensitivity correction yield broadly similar results. However, the observed differences can alter a spectrum's interpretation. For example, we observe that after peak deconvolution the maximum signal wavelength of the IR-RF peak used for dating applications differs by ~3-13 nm between the two methods, depending on sample and diffraction grating. We recommend using calibration lamps to determine a device's SRF but highlight the need to consider issues such as higher-order signals in the choice of filters to establish the SRF's reliable wavelength range. Additionally, we find that a simple and inexpensive fluorescent white light yields an acceptable wavelength calibration comparable to that obtained from a specialized light source.
主题: 数据分析、统计与概率 (physics.data-an); 仪器与探测器 (physics.ins-det)
引用方式: arXiv:2408.07991 [physics.data-an]
  (或者 arXiv:2408.07991v1 [physics.data-an] 对于此版本)
  https://doi.org/10.48550/arXiv.2408.07991
期刊参考: Radiation Measurements 159 (2022), 106876
相关 DOI: https://doi.org/10.1016/j.radmeas.2022.106876

提交历史

来自:Mariana Sontag-González
[v1] 2024年8月15日 星期四 07:40:51 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.data-an
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-08
切换浏览方式为:
physics
physics.ins-det

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站