跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 音频与语音处理

arXiv:2411.01018 (eess)
[提交于 2024年11月5日]

标题:An incremental algorithm based on multichannel non-negative matrix partial co-factorization for ambient denoising in auscultation

作者:Juan De La Torre Cruz, Francisco Jesus Canadas Quesada, Damian Martinez-Munoz, Nicolas Ruiz Reyes, Sebastian Garcia Galan, Julio Jose Carabias Orti
查看论文《An incremental algorithm based on multichannel non-negative matrix partial co-factorization for ambient denoising in auscultation》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The aim of this study is to implement a method to remove ambient noise in biomedical sounds captured in auscultation. We propose an incremental approach based on multichannel non-negative matrix partial co-factorization (NMPCF) for ambient denoising focusing on high noisy environment with a Signal-to-Noise Ratio (SNR) <= -5 dB. The first contribution applies NMPCF assuming that ambient noise can be modelled as repetitive sound events simultaneously found in two single-channel inputs captured by means of different recording devices. The second contribution proposes an incremental algorithm, based on the previous multichannel NMPCF, that refines the estimated biomedical spectrogram throughout a set of incremental stages by eliminating most of the ambient noise that was not removed in the previous stage at the expense of preserving most of the biomedical spectral content. The ambient denoising performance of the proposed method, compared to some of the most relevant state-of-the-art methods, has been evaluated using a set of recordings composed of biomedical sounds mixed with ambient noise that typically surrounds a medical consultation room to simulate high noisy environments with a SNR from -20 dB to -5 dB. Experimental results report that: (i) the performance drop suffered by the proposed method is lower compared to MSS and NLMS; (ii) unlike what happens with MSS and NLMS, the proposed method shows a stable trend of the average SDR and SIR results regardless of the type of ambient noise and the SNR level evaluated; and (iii) a remarkable advantage is the high robustness of the estimated biomedical sounds when the two single-channel inputs suffer from a delay between them.
主题: 音频与语音处理 (eess.AS); 声音 (cs.SD); 信号处理 (eess.SP)
引用方式: arXiv:2411.01018 [eess.AS]
  (或者 arXiv:2411.01018v1 [eess.AS] 对于此版本)
  https://doi.org/10.48550/arXiv.2411.01018
期刊参考: Applied Acoustics, volume 182, November 2021, 108229
相关 DOI: https://doi.org/10.1016/j.apacoust.2021.108229

提交历史

来自:Damian Martínez Muñoz
[v1] 2024年11月5日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.AS
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-11
切换浏览方式为:
eess
cs.SD
eess.SP

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站