跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 流体动力学

arXiv:2411.05090 (physics)
[提交于 2025年4月9日]

标题:Rarefied xenon flow in orificed hollow cathodes

作者:Pierre-Yves C. R. Taunay, Willca Villafana, Sangeeta P. Vinoth, Igor Kaganovich, Andrei Khodak
查看论文《Rarefied xenon flow in orificed hollow cathodes》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:A parametric study is conducted to quantify the effect of the keeper electrode geometry on the neutral flow quantities within orificed hollow cathodes, prior to cathode ignition. The keeper impinges directly on the flow out of the cathode orifice and its geometry strongly influences the product between the pressure in the orifice-keeper region and the distance between cathode and keeper, $P_{ko}\cdot D_{ko}$, a key parameter for successful cathode ignition. A representative cathode equipped with a keeper is simulated using the Direct Simulation Monte Carlo method. The numerical model is first validated with computational results from the literature, and a parametric study is then conducted. Parameters include the cathode pressure-diameter in the range of 1-5 Torr-cm and the following geometric ratios: cathode orifice-to-cathode inner radii in the range of 0.1-0.7, keeper orifice-to-cathode orifice radii in the range of 1-5, and keeper distance-to-cathode-orifice diameter, in the range of 0.5-10. If both keeper and cathode have identical orifice radii, the flow remains subsonic in the cathode orifice-to-keeper region. In most cases, however, the flow becomes underexpanded and supersonic, and the static pressure within the cathode orifice-keeper region is, on average, 4% that of the upstream pressure value. The orifice-keeper region pressure increases with either a decrease in the keeper orifice diameter or an increase in the distance between the cathode orifice plate and the keeper plate, in agreement with literature data. Trends are explained through control-volume-based conservation laws. The ratio of ignition-to-nominal mass flow rates is found to be in the range of 9-120, with a most probable value of 40, in agreement with literature data. This suggests that heater-less cathode ignition at a minimum DC voltage may be achieved by increasing the input mass flow rate by a factor of 40.
评论: 26 pages, 30 figures, 4 tables. Submitted to Journal of Applied Physics. Changes address reviewer comments: title change, text and figure clarifications, and text additions. Significant additions are a method by which mass flow rate may be estimated and a computation of the case for which the keeper orifice diameter is smaller than that of the cathode tube. All results remain unchanged
主题: 流体动力学 (physics.flu-dyn); 等离子体物理 (physics.plasm-ph)
引用方式: arXiv:2411.05090 [physics.flu-dyn]
  (或者 arXiv:2411.05090v1 [physics.flu-dyn] 对于此版本)
  https://doi.org/10.48550/arXiv.2411.05090

提交历史

来自:Pierre-Yves Taunay
[v1] 2025年4月9日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.flu-dyn
< 上一篇   |   下一篇 >
最新 | 近期 | 2025-04
切换浏览方式为:
physics
physics.plasm-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站