跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

统计学 > 应用

arXiv:2411.05580 (stat)
[提交于 2024年11月11日]

标题:Increasing power and robustness in screening trials by testing stored specimens in the control arm

作者:Hormuzd A. Katki, Li C. Cheung
查看论文《Increasing power and robustness in screening trials by testing stored specimens in the control arm》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Background: Screening trials require large sample sizes and long time-horizons to demonstrate mortality reductions. We recently proposed increasing statistical power by testing stored control-arm specimens, called the Intended Effect (IE) design. To evaluate feasibility of the IE design, the US National Cancer Institute (NCI) is collecting blood specimens in the control-arm of the NCI Vanguard Multicancer Detection pilot feasibility trial. However, key assumptions of the IE design require more investigation and relaxation. Methods: We relax the IE design to (1) reduce costs by testing only a stratified sample of control-arm specimens by incorporating inverse-probability sampling weights, (2) correct for potential loss-of-signal in stored control-arm specimens, and (3) correct for non-compliance with control-arm specimen collections. We also examine sensitivity to unintended effects of screening. Results: In simulations, testing all primary-outcome control-arm specimens and a 50% sample of the rest maintains nearly all the power of the IE while only testing half the control-arm specimens. Power remains increased from the IE analysis (versus the standard analysis) even if unintended effects exist. The IE design is robust to some loss-of-signal scenarios, but otherwise requires retest-positive fractions that correct bias at a small loss of power. The IE can be biased and lose power under control-arm non-compliance scenarios, but corrections correct bias and can increase power. Conclusions: The IE design can be made more cost-efficient and robust to loss-of-signal. Unintended effects will not typically reduce the power gain over the standard trial design. Non-compliance with control-arm specimen collections can cause bias and loss of power that can be mitigated by corrections. Although promising, practical experience with the IE design in screening trials is necessary.
主题: 应用 (stat.AP); 方法论 (stat.ME)
引用方式: arXiv:2411.05580 [stat.AP]
  (或者 arXiv:2411.05580v1 [stat.AP] 对于此版本)
  https://doi.org/10.48550/arXiv.2411.05580

提交历史

来自:Hormuzd Katki
[v1] 2024年11月11日 星期一 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

stat.AP
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-11
切换浏览方式为:
stat
stat.ME

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站