跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

计算机科学 > 硬件体系结构

arXiv:2411.09201 (cs)
[提交于 2024年11月14日]

标题:Noncontact Multi-Point Vital Sign Monitoring with mmWave MIMO Radar

作者:Wei Ren, Jiannong Cao, Huansheng Yi, Kaiyue Hou, Miaoyang Hu, Jianqi Wang, Fugui Qi
查看论文《Noncontact Multi-Point Vital Sign Monitoring with mmWave MIMO Radar》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Multi-point vital sign monitoring is essential for providing detailed insights into physiological changes. Traditional single-sensor approaches are inadequate for capturing multi-point vibrations. Existing contact-based solutions, while addressing this need, can cause discomfort and skin allergies, whereas noncontact optical and acoustic methods are highly susceptible to light interference and environmental noise. In this paper, we aim to develop a non-contact, multi-point vital sign monitoring technique using MIMO radar, focused on physically differentiating and precisely measuring chest-wall surface vibrations at multiple points induced by cardiopulmonary mechanical activity. The primary challenges in developing such a technique involve developing algorithms to extract and separate entangled signals, as well as establishing a reliable method for validating detection accuracy. To address these limitations, we introduce MultiVital, a wireless system that leverages mmWave Multiple-input Multiple-output (MIMO) radar for synchronous multi-point vital sign monitoring. It integrates two reference modalities: five-channel seismocardiography (SCG) sensors and a one-channel electrocardiogram (ECG) electrode, enabling comprehensive radar-based research and performance validation across multiple physiological metrics. Additionally, we have developed a multi-modal signal processing framework, consisting of a radar signal processing module, an SCG calibration module, and a spatial alignment scheme. To evaluate the radar signal processing module, we conducted mathematical derivation and simulation. The experimental results indicate that the noncontact MultiVital system achieves multi-point synchronous monitoring with high precision, highly consistent with the results from reference modalities.
评论: 15 pages
主题: 硬件体系结构 (cs.AR); 信号处理 (eess.SP)
引用方式: arXiv:2411.09201 [cs.AR]
  (或者 arXiv:2411.09201v1 [cs.AR] 对于此版本)
  https://doi.org/10.48550/arXiv.2411.09201

提交历史

来自:Wei Ren
[v1] 2024年11月14日 星期四 05:51:46 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.AR
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-11
切换浏览方式为:
cs
eess.SP

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站