跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 仪器与探测器

arXiv:2412.02180 (physics)
[提交于 2024年12月4日]

标题:Optical losses as a function of beam position on the mirrors in a 285-m suspended Fabry-Perot cavity

作者:Y. Zhao, M. Vardaro, E. Capocasa, J. Ding, Y. Guo, M. Lequime, M. Barsuglia
查看论文《Optical losses as a function of beam position on the mirrors in a 285-m suspended Fabry-Perot cavity》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Reducing optical losses is crucial for reducing quantum noise in gravitational-wave detectors. Losses are the main source of degradation of the squeezed vacuum. Frequency dependent squeezing obtained via a filter cavity is currently used to reduce quantum noise in the whole detector bandwidth. Such filter cavities are required to have high finesse in order to produce the optimal squeezing angle rotation and the presence of losses is particularly detrimental for the squeezed beam, as it does multiple round trip within the cavity. Characterising such losses is crucial to assess the quantum noise reduction achievable. In this paper we present an in-situ measurement of the optical losses, done for different positions of the beam on the mirrors of the Virgo filter cavity. We implemented an automatic system to map the losses with respect to the beam position on the mirrors finding that optical losses depend clearly on the beam hitting position on input mirror, varying from 42 ppm to 87 ppm, while they are much more uniform when we scan the end mirror (53 ppm to 61 ppm). We repeated the measurements on several days, finding a statistical error smaller than 4 ppm. The lowest measured losses are not much different with respect to those estimated from individual mirror characterisation performed before the installation (30.3 - 39.3 ppm). This means that no major loss mechanism has been neglected in the estimation presented here. The larger discrepancy found for some beam positions is likely to be due to contamination. In addition to a thorough characterisation of the losses, the methodology described in this paper allowed to find an optimal cavity axis position for which the cavity round trip losses are among the lowest ever measured. This work can contribute to achieve the very challenging losses goals for the optical cavities of the future gravitational-wave detectors.
评论: This work has been accepted for publication in Physical Review Applied. The final version is available at https://journals.aps.org/prapplied/abstract/10.1103/PhysRevApplied.22.054040
主题: 仪器与探测器 (physics.ins-det); 光学 (physics.optics); 量子物理 (quant-ph)
引用方式: arXiv:2412.02180 [physics.ins-det]
  (或者 arXiv:2412.02180v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.2412.02180
期刊参考: Phys. Rev. Applied 22, 054040, 2024
相关 DOI: https://doi.org/10.1103/PhysRevApplied.22.054040

提交历史

来自:Yuhang Zhao
[v1] 2024年12月4日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-12
切换浏览方式为:
physics
physics.optics
quant-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站