标题:Calibration of the mechanical boundary conditions for a patient-specific thoracic aorta model including the heart motion effect

作者:Leonardo Geronzi, Aline Bel-Brunon, Antonio Martinez, Michel Rochette, Marco Sensale, Olivier Bouchot, Alain Lalande, Siyu Lin, Pier Paolo Valentini, Marco Evangelos Biancolini
查看论文《Calibration of the mechanical boundary conditions for a patient-specific thoracic aorta model including the heart motion effect》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objective: we propose a procedure for calibrating 4 parameters governing the mechanical boundary conditions (BCs) of a thoracic aorta (TA) model derived from one patient with ascending aortic aneurysm. The BCs reproduce the visco-elastic structural support provided by the soft tissue and the spine and allow for the inclusion of the heart motion effect. Methods: we first segment the TA from magnetic resonance imaging (MRI) angiography and derive the heart motion by tracking the aortic annulus from cine-MRI. A rigid-wall fluid-dynamic simulation is performed to derive the time-varying wall pressure field. We build the finite element model considering patient-specific material properties and imposing the derived pressure field and the motion at the annulus boundary. The calibration, which involves the zero-pressure state computation, is based on purely structural simulations. After obtaining the vessel boundaries from the cine-MRI sequences, an iterative procedure is performed to minimize the distance between them and the corresponding boundaries derived from the deformed structural model. A strongly-coupled fluid-structure interaction (FSI) analysis is finally performed with the tuned parameters and compared to the purely structural simulation. Results and Conclusion: the calibration with structural simulations allows to reduce maximum and mean distances between image-derived and simulation-derived boundaries from 8.64 mm to 6.37 mm and from 2.24 mm to 1.83 mm, respectively. The maximum root mean square error between the deformed structural and FSI surface meshes is 0.19 mm. This procedure may prove crucial for increasing the model fidelity in replicating the real aortic root kinematics.
主题: 医学物理 (physics.med-ph); 数值分析 (cs.NA); 数值分析 (math.NA)
引用方式: arXiv:2503.02485 [physics.med-ph]
  (或者 arXiv:2503.02485v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2503.02485
期刊参考: Volume: 70 Issue: 11, November 2023, IEEE Transaction on Biomedical Engineering
相关 DOI: https://doi.org/10.1109/TBME.2023.3287680

提交历史

来自:Leonardo Geronzi
[v1] 2025年3月5日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2025-03
切换浏览方式为:
physics
cs.NA
math.NA

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站