标题:Heat transfer and mixing in initiated Chemical Vapor Deposition analyzed by in-situ gas composition sensing

作者:Simon Shindler, Rong Yang
查看论文《Heat transfer and mixing in initiated Chemical Vapor Deposition analyzed by in-situ gas composition sensing》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Studies of iCVD kinetics often make assumptions about the iCVD vapor phase that have been challenging to validate experimentally. We address this gap by investigating heat transfer and mixing in the iCVD reactor using in-situ gas composition sensing. Our work allows practitioners of iCVD to estimate the degree of mixing and temperature profile in the vapor phase based on reactor dimensions and process variables such as chamber pressure. We begin by using dimensional analysis to simplify the parameter space governing heat transfer and mixing, identifying key dimensionless groups that capture the dominant physics. We find that the degree of mixing in the reactor is primarily determined by the Peclet number (Pe), and heat transfer is primarily determined by the Knudsen number (Kn). Multiphysics simulations of the iCVD reactor provide visualizations of non-ideal mixing and allow us to identify the critical Pe above which the well-mixed assumption may begin to break down. To verify that the well-mixed assumption applies to iCVD at low Pe, we measured the residence time distribution (RTD) for argon and isopropanol flowing at 1 sccm, finding a close match to the well-mixed model. We used a Pirani pressure gauge for composition sensing to measure the RTD. We demonstrate the Pirani gauge to be a precise gas composition sensor, which is more modular and less expensive than methods like in-situ infrared spectroscopy and mass spectrometry. We then address heat transfer by measuring thermal diffusion from the filament at a range of pressures in argon and isopropanol. We quantified the effects of non-ideal heat transfer at low pressures and identified a critical Kn, above which heat transfer is independent of pressure. Measurement of thermally driven pressure changes in batch mode enables us to define and model an "effective temperature" for the reactor, matching the thermal diffusion model.
主题: 经典物理 (physics.class-ph); 流体动力学 (physics.flu-dyn)
引用方式: arXiv:2503.16373 [physics.class-ph]
  (或者 arXiv:2503.16373v1 [physics.class-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2503.16373

提交历史

来自:Rong Yang
[v1] 2025年3月20日 星期四 17:35:31 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.class-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2025-03
切换浏览方式为:
physics
physics.flu-dyn

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站