跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 图像与视频处理

arXiv:2505.01741 (eess)
[提交于 2025年5月6日]

标题:CLOG-CD: Curriculum Learning based on Oscillating Granularity of Class Decomposed Medical Image Classification

作者:Asmaa Abbas, Mohamed Gaber, Mohammed M. Abdelsamea
查看论文《CLOG-CD: Curriculum Learning based on Oscillating Granularity of Class Decomposed Medical Image Classification》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Curriculum learning strategies have been proven to be effective in various applications and have gained significant interest in the field of machine learning. It has the ability to improve the final model's performance and accelerate the training process. However, in the medical imaging domain, data irregularities can make the recognition task more challenging and usually result in misclassification between the different classes in the dataset. Class-decomposition approaches have shown promising results in solving such a problem by learning the boundaries within the classes of the data set. In this paper, we present a novel convolutional neural network (CNN) training method based on the curriculum learning strategy and the class decomposition approach, which we call CLOG-CD, to improve the performance of medical image classification. We evaluated our method on four different imbalanced medical image datasets, such as Chest X-ray (CXR), brain tumour, digital knee X-ray, and histopathology colorectal cancer (CRC). CLOG-CD utilises the learnt weights from the decomposition granularity of the classes, and the training is accomplished from descending to ascending order (i.e., anti-curriculum technique). We also investigated the classification performance of our proposed method based on different acceleration factors and pace function curricula. We used two pre-trained networks, ResNet-50 and DenseNet-121, as the backbone for CLOG-CD. The results with ResNet-50 show that CLOG-CD has the ability to improve classification performance with an accuracy of 96.08% for the CXR dataset, 96.91% for the brain tumour dataset, 79.76% for the digital knee X-ray, and 99.17% for the CRC dataset, compared to other training strategies. In addition, with DenseNet-121, CLOG-CD has achieved 94.86%, 94.63%, 76.19%, and 99.45% for CXR, brain tumour, digital knee X-ray, and CRC datasets, respectively
评论: Published in: IEEE Transactions on Emerging Topics in Computing
主题: 图像与视频处理 (eess.IV); 计算机视觉与模式识别 (cs.CV)
引用方式: arXiv:2505.01741 [eess.IV]
  (或者 arXiv:2505.01741v1 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.2505.01741
相关 DOI: https://doi.org/10.1109/TETC.2025.3562620

提交历史

来自:Mohammed Abdelsamea
[v1] 2025年5月6日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2025-05
切换浏览方式为:
eess
cs.CV

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站