标题:Global Maxwell Tomography Using the Volume-Surface Integral Equation for Improved Estimation of Electrical Properties

作者:Ilias Giannakopoulos, José E. Cruz Serrallés, Jan Paška, Martijn A. Cloos, Ryan Brown, Riccardo Lattanzi
查看论文《Global Maxwell Tomography Using the Volume-Surface Integral Equation for Improved Estimation of Electrical Properties》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objective: Global Maxwell Tomography (GMT) is a noninvasive inverse optimization method for the estimation of electrical properties (EP) from magnetic resonance (MR) measurements. GMT uses the volume integral equation (VIE) in the forward problem and assumes that the sample has negligible effect on the coil currents. Consequently, GMT calculates the coil's incident fields with an initial EP distribution and keeps them constant for all optimization iterations. This can lead to erroneous reconstructions. This work introduces a novel version of GMT that replaces VIE with the volume-surface integral equation (VSIE), which recalculates the coil currents at every iteration based on updated EP estimates before computing the associated fields. Methods: We simulated an 8-channel transceiver coil array for 7 T brain imaging and reconstructed the EP of a realistic head model using VSIE-based GMT. We built the coil, collected experimental MR measurements, and reconstructed EP of a two-compartment phantom. Results: In simulations, VSIE-based GMT outperformed VIE-based GMT by at least 12% for both EP. In experiments, the relative difference with respect to probe-measured EP values in the inner (outer) compartment was 13% (26%) and 17% (33%) for the permittivity and conductivity, respectively. Conclusion: The use of VSIE over VIE enhances GMT's performance by accounting for the effect of the EP on the coil currents. Significance: VSIE-based GMT does not rely on an initial EP estimate, rendering it more suitable for experimental reconstructions compared to the VIE-based GMT.
评论: 12 pages, 8 figures, 2 tables, Article accepted for publication in IEEE Transactions on Biomedical Engineering
主题: 计算工程、金融与科学 (cs.CE); 信号处理 (eess.SP)
引用方式: arXiv:2505.14546 [cs.CE]
  (或者 arXiv:2505.14546v1 [cs.CE] 对于此版本)
  https://doi.org/10.48550/arXiv.2505.14546

提交历史

来自:Ilias Giannakopoulos Dr
[v1] 2025年5月20日 星期二 16:02:30 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.CE
< 上一篇   |   下一篇 >
最新 | 近期 | 2025-05
切换浏览方式为:
cs
eess.SP

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站