跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

计算机科学 > 计算机视觉与模式识别

arXiv:2510.00723 (cs)
[提交于 2025年10月1日]

标题:Deep learning motion correction of quantitative stress perfusion cardiovascular magnetic resonance

作者:Noortje I. P. Schueler, Nathan C. K. Wong, Richard J. Crawley, Josien P. W. Pluim, Amedeo Chiribiri, Cian M. Scannell
查看论文《Deep learning motion correction of quantitative stress perfusion cardiovascular magnetic resonance》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Background: Quantitative stress perfusion cardiovascular magnetic resonance (CMR) is a powerful tool for assessing myocardial ischemia. Motion correction is essential for accurate pixel-wise mapping but traditional registration-based methods are slow and sensitive to acquisition variability, limiting robustness and scalability. Methods: We developed an unsupervised deep learning-based motion correction pipeline that replaces iterative registration with efficient one-shot estimation. The method corrects motion in three steps and uses robust principal component analysis to reduce contrast-related effects. It aligns the perfusion series and auxiliary images (arterial input function and proton density-weighted series). Models were trained and validated on multivendor data from 201 patients, with 38 held out for testing. Performance was assessed via temporal alignment and quantitative perfusion values, compared to a previously published registration-based method. Results: The deep learning approach significantly improved temporal smoothness of time-intensity curves (p<0.001). Myocardial alignment (Dice = 0.92 (0.04) and 0.91 (0.05)) was comparable to the baseline and superior to before registration (Dice = 0.80 (0.09), p<0.001). Perfusion maps showed reduced motion, with lower standard deviation in the myocardium (0.52 (0.39) ml/min/g) compared to baseline (0.55 (0.44) ml/min/g). Processing time was reduced 15-fold. Conclusion: This deep learning pipeline enables fast, robust motion correction for stress perfusion CMR, improving accuracy across dynamic and auxiliary images. Trained on multivendor data, it generalizes across sequences and may facilitate broader clinical adoption of quantitative perfusion imaging.
评论: Under review
主题: 计算机视觉与模式识别 (cs.CV)
引用方式: arXiv:2510.00723 [cs.CV]
  (或者 arXiv:2510.00723v1 [cs.CV] 对于此版本)
  https://doi.org/10.48550/arXiv.2510.00723

提交历史

来自:Cian M. Scannell
[v1] 2025年10月1日 星期三 09:59:48 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.CV
< 上一篇   |   下一篇 >
最新 | 近期 | 2025-10
切换浏览方式为:
cs

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站