跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

计算机科学 > 性能

arXiv:2510.15237 (cs)
[提交于 2025年10月17日]

标题:Impact of AI-Triage on Radiologist Report Turnaround Time: Real-World Time-Savings and Insights from Model Predictions

作者:Yee Lam Elim Thompson, Jonathan Fergus, Jonathan Chung, Jana G. Delfino, Weijie Chen, Gary M. Levine, Frank W. Samuelson
查看论文《Impact of AI-Triage on Radiologist Report Turnaround Time: Real-World Time-Savings and Insights from Model Predictions》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objective: To quantify the impact of workflow parameters on time-savings in report turnaround time (TAT) due to an AI-triage device that prioritized pulmonary embolism (PE) in chest CT pulmonary angiography (CTPA) exams. Methods: This retrospective study analyzed 11252 adult CTPA exams conducted for suspected PE at a single tertiary academic medical center. Data was divided into two periods: pre-AI and post-AI. For PE-positive exams, TAT - defined as the duration from patient scan completion to the first preliminary report completion - was compared between the two periods. Time-savings were reported separately for work-hour and off-hour cohorts. To characterize radiologist workflow, 527234 records were retrieved from the PACS and workflow parameters such as exam inter-arrival time and radiologist read-time extracted. These parameters were input into a computational model to predict time-savings following deployment of an AI-triage device and to study the impact of workflow parameters. Results: The pre-AI dataset included 4694 chest CTPA exams with 13.3% being PE-positive. The post-AI dataset comprised 6558 exams with 16.2% being PE-positive. The mean TAT for pre-AI and post-AI during work hours are 68.9 [95% CI" 55.0, 82.8] and 46.7 [38.1, 55.2] minutes respectively, and those during off-hours are 44.8 [33.7, 55.9] and 42.0 [33.6, 50.3] minutes. Clinically-observed time-savings during work hours (22.2 [95% CI: 5.85, 38.6] minutes) were significant (p=0.004), while off-hour (2.82 [-11.1, 16.7] minutes) were not (p=0.345). Observed time-savings aligned with model predictions (29.6 [95% range: 23.2, 38.1] minutes for work hours; 2.10 [1.76, 2.58] minutes for off-hours). Discussion: Consideration and quantification of clinical workflow contribute to an accurate assessment of the expected time-savings in TAT following deployment of an AI-triage device.
主题: 性能 (cs.PF)
引用方式: arXiv:2510.15237 [cs.PF]
  (或者 arXiv:2510.15237v1 [cs.PF] 对于此版本)
  https://doi.org/10.48550/arXiv.2510.15237
相关 DOI: https://doi.org/10.1016/j.jacr.2025.07.033

提交历史

来自:Yee Lam Elim Thompson
[v1] 2025年10月17日 星期五 02:00:07 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.PF
< 上一篇   |   下一篇 >
最新 | 近期 | 2025-10
切换浏览方式为:
cs

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站