标题:Interstitial dual-mode ultrasound with a 3-mm MR-compatible catheter for image-guided HIFU and directional in-vitro tissue ablations

作者:Thomas Biscaldi, Romain l'Huillier, Laurent Milot, W Apoutou N'Djin
查看论文《Interstitial dual-mode ultrasound with a 3-mm MR-compatible catheter for image-guided HIFU and directional in-vitro tissue ablations》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Current interstitial techniques of tumor ablation face challenges that ultrasound technologies could meet. The ablation radius and directionality of the ultrasound beam could improve the efficiency and precision. Here, a 9gauge MR-compatible dual-mode ultrasound catheter prototype was experimentally evaluated for Ultrasound Imageguided High Intensity Focused Ultrasound (USgHIFU) conformal ablations. The prototype consisted of 64 piezocomposite linear array elements and was driven by an open research programmable dual-mode ultrasound platform. After verifying the US-image guidance capabilities of the prototype, the HIFU output performances (dynamic focusing and HIFU intensities) were quantitatively characterized, together with the associated 3D HIFU-induced thermal heating in tissue phantoms (using MR thermometry). Finally, the ability to produce robustly HIFU-induced thermal ablations in in-vitro liver was studied experimentally and compared to numerical modeling. Investigations of several HIFU dynamic focusing allowed overcoming the challenges of miniaturizing the device: mono-focal focusing maximized deep energy deposition, while multi-focal strategies eliminated grating lobes. The linear-array design of the prototype made it possible to produce interstitial ultrasound images of tissue and tumor mimics in situ. Multi-focal pressure fields were generated without grating lobes and transducer surface intensities reached up to Isapa =14 W$\bullet$cm -2 . Seventeen elementary thermal ablations were performed in vitro. Rotation of the catheter proved the directionality of ablation, sparing non-targeted tissue. This experimental proof of concept demonstrates the feasibility of treating volumes comparable to those of primary solid tumors with a miniaturized USgHIFU catheter whose dimensions are close to those of tools traditionally used in interventional radiology, while offering new functionalities.
主题: 经典物理 (physics.class-ph)
引用方式: arXiv:2511.04207 [physics.class-ph]
  (或者 arXiv:2511.04207v1 [physics.class-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2511.04207
期刊参考: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2024, 71 (11), pp.1588-1605

提交历史

来自:W. Apoutou N'DJIN
[v1] 2025年11月6日 星期四 09:13:28 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.class-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2025-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站