跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

凝聚态物理 > 材料科学

arXiv:2512.03372 (cond-mat)
[提交于 2025年12月3日]

标题:On the Accuracy of Atomic Resolution Electrostatic Measurements in 2D Materials

作者:Rafael V. Ferreira, Sebastian Calderon V., Paulo J. Ferreira
查看论文《On the Accuracy of Atomic Resolution Electrostatic Measurements in 2D Materials》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The use of differential phase contrast (DPC) in scanning transmission electron microscopy (STEM) has shown much promise for directly investigating the functional properties of a material system, leveraging the natural coupling between the electron probe and atomic-scale electric fields to map the electrostatic configuration within a sample. However, the high sensitivity of these measurements makes them particularly vulnerable to variations in both sample properties and the configuration of the instrument, stressing the need for robust methodologies to ensure more accurate analyses. In this work, the influence of key instrumental parameters - probe convergence angle, defocus and two-fold astigmatism - on atomic-resolution segmented-detector DPC-STEM measurements is evaluated through extensive image simulations. Results show that the limit of interpretability for a 21 mrad defocused probe is found at a magnitude of 4 nm, where electrostatic field magnitude can be underestimated by about 16 % in overfocus and just above 10 % in underfocus. Equivalent results for a 30 mrad probe demonstrate underestimated values around 30 % at overfocus and 20 % for underfocus, at a lower interpretability limit of 3 nm. Two-fold astigmatism introduces orientation dependent variations that surpass 40 % for magnitudes below 3 nm, but a reduction in sensitivity to the aberration is observed when oriented along detector-segment edges. Overall, the analysis confirms the sensitivity and usefulness of the scattergram-based method and underscores the importance of optimized instrumental alignment for accurate CoM based STEM imaging.
评论: 22 pages, 14 figures, submitted to Ultramicroscopy
主题: 材料科学 (cond-mat.mtrl-sci); 应用物理 (physics.app-ph)
引用方式: arXiv:2512.03372 [cond-mat.mtrl-sci]
  (或者 arXiv:2512.03372v1 [cond-mat.mtrl-sci] 对于此版本)
  https://doi.org/10.48550/arXiv.2512.03372

提交历史

来自:Rafael Ferreira
[v1] 2025年12月3日 星期三 02:09:54 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cond-mat.mtrl-sci
< 上一篇   |   下一篇 >
最新 | 近期 | 2025-12
切换浏览方式为:
cond-mat
physics.app-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站