跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

计算机科学 > 人机交互

arXiv:2601.00670 (cs)
[提交于 2026年1月2日]

标题:Wave2Word: A Multimodal Transformer Framework for Joint EEG-Text Alignment and Multi-Task Representation Learning in Neurocritical Care

作者:Argha Kamal Samanta, Deepak Mewada, Monalisa Sarma, Debasis Samanta
查看论文《Wave2Word: A Multimodal Transformer Framework for Joint EEG-Text Alignment and Multi-Task Representation Learning in Neurocritical Care》的 PDF
查看中文 PDF 查看原文 PDF EasyResearch 阅读
摘要:Continuous electroencephalography (EEG) is routinely used in neurocritical care to monitor seizures and other harmful brain activity, including rhythmic and periodic patterns that are clinically significant. Although deep learning methods have achieved high accuracy in seizure detection, most existing approaches remain seizure-centric, rely on discrete-label supervision, and are primarily evaluated using accuracy-based metrics. A central limitation of current EEG modeling practice is the weak correspondence between learned representations and how EEG findings are interpreted and summarized in clinical workflows. Harmful EEG activity exhibits overlapping patterns, graded expert agreement, and temporal persistence, which are not well captured by classification objectives alone. This work proposes a multimodal EEG representation learning framework that integrates signal-domain modeling with structured clinical language supervision. First, raw EEG is transformed into a longitudinal bipolar montage and time-frequency representations. Second, dual transformer-based encoders model complementary temporal and frequency-centric dependencies and are fused using an adaptive gating mechanism. Third, EEG embeddings are aligned with structured expert consensus descriptions through a contrastive objective. Finally, an EEG-conditioned text reconstruction loss is introduced as a representation-level constraint alongside standard classification loss. Experimental evaluation using a controlled train-validation-test split achieves a six-class test accuracy of 0.9797. Ablation analyses show that removing contrastive alignment reduces cross-modal retrieval performance from Recall@10 of 0.3390 to 0.0045, despite minimal change in classification accuracy. These findings demonstrate that discriminative accuracy does not reliably reflect representation quality for clinically meaningful EEG modeling.
主题: 人机交互 (cs.HC)
引用方式: arXiv:2601.00670 [cs.HC]
  (或者 arXiv:2601.00670v1 [cs.HC] 对于此版本)
  https://doi.org/10.48550/arXiv.2601.00670

提交历史

来自:Argha Kamal Samanta
[v1] 2026年1月2日 星期五 12:35:12 UTC
全文链接:

访问论文:

  • 查看中文 PDF
  • 查看原文 PDF
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.HC
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-01
切换浏览方式为:
cs

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站