标题:Unravelling Challenges in Heating Power Measurements for Magnetic Hyperthermia -- the RADIOMAG Round Robin Study Revisited

作者:Lise G. Hanson, Daniel Ortega, Cathrine Frandsen
查看论文《Unravelling Challenges in Heating Power Measurements for Magnetic Hyperthermia -- the RADIOMAG Round Robin Study Revisited》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Non-adiabatic AC calorimetry is the most widely used technique for estimating the heating power of magnetic nanoparticles in magnetic hyperthermia. However, it is prone to systematic errors which lead to a standard deviation in the intrinsic loss power (ILP) of approximately 30-40%, as revealed by the RADIOMAG EU COST Action TD1402 round-robin study involving 21 European laboratories. In this study, we re-examine the RADIOMAG dataset to both uncover previously unreported instrumentation issues, and to explore more deeply some of the reported instrumentation issues. We identify four common sources of error: i) Insufficient temperature resolution, ii) AC-field sensitive thermometers, iii) Non-physical temperature oscillations, and iv) Apparent non-linear heat loss. Based on these findings, we propose criteria for sufficient measurement quality and apply them to re-estimate the ILP values. These results have a standard deviation of 18-30%., demonstrating that addressing instrumentation and analysis issues can improve measurement reliability and decrease the inter-laboratory deviation by up to 38%. When re-estimating ILP, we used the initial slope method, arguing that the corrected slope method, which was previously used to investigate the RADIOMAG data, could introduce misleading interpretations of systematic ILP deviations due to sub-optimal measurement conditions and the unnoticed influence of non-linear heat losses. However, we emphasise that the corrected slope method is preferred, given a linear heat loss. Based on our analysis, we introduce a diagnostic protocol by using slope curves - a simple yet effective plot type - for identifying and solving common instrumentation challenges proactively before the data acquisition phase.
主题: 应用物理 (physics.app-ph)
引用方式: arXiv:2606.06045 [physics.app-ph]
  (或者 arXiv:2606.06045v1 [physics.app-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2606.06045

提交历史

来自:Lise Hanson
[v1] 2026年6月4日 星期四 11:40:17 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.app-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-06
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站