跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 光学

arXiv:2607.03021 (physics)
[提交于 2026年7月3日]

标题:MEMS Fiber-Tip Photoacoustic Spectrometer for In Situ Microscale Trace Gas Sensing

作者:Xingjie Liu, Mengqi Wu, Ping Lu
查看论文《MEMS Fiber-Tip Photoacoustic Spectrometer for In Situ Microscale Trace Gas Sensing》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:To meet the stringent requirements for miniaturized and highly sensitive trace gas sensing in space-constrained scenarios, including power equipment monitoring, minimally invasive biomedical diagnostics, and in situ lithium-battery analysis, we report a MEMS-integrated fiber-tip photoacoustic spectrometer (MFPAS). The device incorporates a Fabry-Perot (F-P) photoacoustic sensor formed by directly butt-coupling a single-mode fiber (SMF) to a 3 mm x 3 mm MEMS chip with a 100-nm-thick low-pressure chemical vapor deposition (LPCVD) Si$_3$N$_4$ diaphragm. The resulting approximately 200-$\mu$m deep silicon microcavity functions simultaneously as a photoacoustic gas cell and an acoustic confinement cavity. A micro-aperture fabricated at the diaphragm periphery by focused ion beam (FIB) milling serves as both a gas diffusion channel and an acoustic high-pass filter, suppressing ambient low-frequency pressure fluctuations and stabilizing the F-P quadrature point without active servo control. In gas-phase measurements, the sensor achieves a noise-equivalent concentration (NEC) of 58.5 ppb@1s, with a rapid response time of 6 s. Benefiting from its ultra-small cavity volume of approximately 1.5 nL, the device is further adapted through structural packaging for in situ dissolved gas analysis in transformer oil, where it achieves an NEC of 230 ppb@1s and a T90 response time of 320 s in the oil phase. By combining nanoliter-scale detection volume, ppb-level sensitivity, rapid response, and wafer-scale batch fabrication compatibility, the proposed MFPAS bridges MEMS diaphragm micromachining and FIB-enabled gas exchange engineering. This design overcomes the intrinsic gas-exchange limitation of conventional sealed-diaphragm optical microphones and offers significant potential for power equipment monitoring and in situ health diagnostics.
评论: 15 pages, 8 figures
主题: 光学 (physics.optics)
引用方式: arXiv:2607.03021 [physics.optics]
  (或者 arXiv:2607.03021v1 [physics.optics] 对于此版本)
  https://doi.org/10.48550/arXiv.2607.03021

提交历史

来自:Ping Lu
[v1] 2026年7月3日 星期五 07:10:01 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.optics
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-07
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站