跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

计算机科学 > 硬件体系结构

arXiv:2607.14747 (cs)
[提交于 2026年7月16日 (v1),最后修订于 2026年11月24日 (此版本, v2)]

标题:Toward Energy-Efficient and Low-Power Arrhythmia Detection for Wearable Devices

作者:Floriaan Bulten, Yawar Rasheed, Arlene John, Vincenzo Stoico, Ghayoor Gillani
查看论文《Toward Energy-Efficient and Low-Power Arrhythmia Detection for Wearable Devices》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Cardiovascular diseases are the leading cause of death worldwide, and conditions such as arrhythmia often require long-term monitoring for effective detection and diagnosis. However, current wearable monitoring devices are bulky, uncomfortable, and typically rely on clinicians to manually evaluate electrocardiograms (ECGs). While Deep Learning (DL) algorithms have shown superior performance in arrhythmia detection and classification, their computational complexity coupled with high power consumption limit deployment in wearable devices. To address this challenge, this paper investigates the use of approximation techniques to reduce the power and energy consumption of DL architectures while maintaining acceptable classification performance. Specifically, techniques such as data precision reduction and approximate multiplication are investigated in a state-of-the-art DL model and its corresponding hardware architecture. The model is trained and validated using the MIT-BIH Arrhythmia Database, and hardware implementations employing various approximate multipliers are synthesized and evaluated. Compared with the state-of-the-art 8.75 {\mu}W (and 2.08 {\mu}J) reference architecture, our proposed architecture consumes 3.07 {\mu}W (and 2.17 {\mu}J) at 12 kHz, showing 64.9% reduction in power consumption while providing an acceptable output quality, i.e., 93.7% classification accuracy and 92.1% sensitivity. At 100 MHz, our proposed architecture consumes 9.45 mW (and 0.8 {\mu}J), showing 61.5% reduction in energy consumption as compared to the state-of-the-art architecture. These results demonstrate that our proposed approximations significantly extend wearable device battery life while preserving the required arrhythmia classification performance.
主题: 硬件体系结构 (cs.AR); 机器学习 (cs.LG); 神经与演化计算 (cs.NE); 性能 (cs.PF)
引用方式: arXiv:2607.14747 [cs.AR]
  (或者 arXiv:2607.14747v2 [cs.AR] 对于此版本)
  https://doi.org/10.48550/arXiv.2607.14747

提交历史

来自:Vincenzo Stoico
[v1] 2026年7月16日 星期四 09:31:31 UTC (769 KB)
[v2] 2026年11月24日 星期二 23:07:25 UTC (769 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.AR
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
cs
cs.LG
cs.NE
cs.PF

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站