跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:2607.29253 (physics)
[提交于 2026年7月31日]

标题:CBCT-IQ: A Publicly Available Annotated Cone-Beam CT Dataset for Image Quality Assessment and Benchmarking

作者:Sepideh Hatamikia, Anna Breger, Clemens Karner, Birgit Pohn, Poorya MohammadiNasab, Martin Buschmann, Stephanie Nougaret, Laura Haddad, Ali Abbasian Ardakani, Afshin Mohammadi, Paul Apfaltrer, Wolfgang Birkfellner, Alfred Pohl, Ander Biguri, Gernot Kronreif, Carola-Bibiane Schönlieb, Tess Reynolds
查看论文《CBCT-IQ: A Publicly Available Annotated Cone-Beam CT Dataset for Image Quality Assessment and Benchmarking》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Medical image quality plays a critical role in diagnostic accuracy, especially in X-ray-based imaging modalities such as cone-beam computed tomography (CBCT), where image quality must be balanced against radiation dose. While expert visual evaluation remains the clinical standard for image quality evaluation, it is time-consuming, subjective and affected by inter-observer variability, emphasizing the need for reliable quantitative image quality assessment (IQA) methods. However, the development and validation of such IQA methods have been limited by the lack of publicly available CBCT datasets with expert image quality annotations. In this study, we provide the first open-access CBCT IQA dataset containing 1,764 annotated image slices acquired using systematic variations in image acquisition and reconstruction parameters. Three clinical experts graded the overall image quality and a predefined regions of interest (ROI) using a four-level scoring scheme. In addition, we benchmark 26 full reference- and no reference-based IQA measures against expert annotations and introduce an exploratory IQA measure-based ranking capable of distinguishing subtle image quality differences. This dataset introduced a standardized benchmark for future CBCT IQA research and provides a valuable resource for the development and validation of new IQA methods, enabling reproducible research and advancing CBCT IQA.
主题: 医学物理 (physics.med-ph); 计算机视觉与模式识别 (cs.CV)
引用方式: arXiv:2607.29253 [physics.med-ph]
  (或者 arXiv:2607.29253v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2607.29253

提交历史

来自:Sepideh Hatamikia Ass. -Prof. Dr.
[v1] 2026年7月31日 星期五 10:24:20 UTC (1,855 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-08
切换浏览方式为:
physics
cs.CV

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站