计算机科学 > 计算工程、金融与科学

arXiv:2607.29446 (cs)
[提交于 2026年7月31日 (v1),最后修订于 2026年11月25日 (此版本, v2)]

标题:Mechanical Modeling of Braided Neurovascular Flow Diverters using a Beam-to-Beam and Beam-to-Surface Contact Formulation

作者:Martin Frank, Ivo Steinbrecher, Matthias Mayr, Alexander Popp
查看论文《Mechanical Modeling of Braided Neurovascular Flow Diverters using a Beam-to-Beam and Beam-to-Surface Contact Formulation》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Braided neurovascular flow diverters are widely used for the endovascular treatment of intracranial aneurysms. Their mechanical response and deployed configuration are governed by the interaction of many slender, interwoven wires, which makes the numerical simulation of the complete device a challenging problem. This work presents a detailed mechanical model of complete braided flow diverters that integrates geometrically exact beam mechanics and contact mechanics into one consistent implicit finite element formulation. Every wire is modeled as a geometrically exact Simo-Reissner beam, which consistently describes large rotations and curved reference configurations. The interactions between the wires are captured by a beam-to-beam contact formulation with a history-dependent gap function that prevents unintended wire crossings. The interaction with surrounding tubular structures, such as microcatheters or crimping devices, is captured by a beam-to-surface contact formulation. A parametric description of interwoven braided geometries enables systematic control of design parameters such as wire count, braiding angle, device length, and interweaving pattern. The model is assessed by means of three test cases from the literature. A tensile test investigates the length-diameter relation and the axial force response, and a radial compression test addresses the pressure-diameter behavior. A stepwise compression example evaluates geometry-sensitive quantities, including local wire distance, helix angle, porosity, and metal coverage ratio. The results show that the model captures both the characteristic mechanical response and clinically relevant geometric quantities of braided flow diverters.
主题: 计算工程、金融与科学 (cs.CE)
引用方式: arXiv:2607.29446 [cs.CE]
  (或者 arXiv:2607.29446v2 [cs.CE] 对于此版本)
  https://doi.org/10.48550/arXiv.2607.29446

提交历史

来自:Martin Frank
[v1] 2026年7月31日 星期五 14:11:08 UTC (27,029 KB)
[v2] 2026年11月25日 星期三 07:26:11 UTC (19,413 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.CE
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
cs

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站