标题:Saturation-Aware Predictive Quantization for Low-Power ECG Acquisition: A Benchmark of Taylor, Adaptive-Order, Kalman, and LSTM Predictors

作者:Xiyuan Feng, Yuxiang Zhao, Jie Xiong, Dian Lin, Yunlei Zhong, Wei Liu, Zhongheng Ji, Ruiyu Tian, Chenhao Zhuo, Yue Yin
查看论文《Saturation-Aware Predictive Quantization for Low-Power ECG Acquisition: A Benchmark of Taylor, Adaptive-Order, Kalman, and LSTM Predictors》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Wearable electrocardiogram (ECG) monitors require energy-efficient analog-to-digital converters (ADCs), yet conventional successive-approximation-register (SAR) ADCs repeatedly resolve slowly varying most significant bits. Predictive quantization (PQ) instead estimates the next sample and quantizes only the residual, thereby reducing the required conversion depth. Its principal failure mode is residual saturation, which occurs when prediction error exceeds the residual ADC range and is irreversibly clipped. We compared four one-step-ahead predictors under a common 10-bit, saturation-aware PQ model with residual widths from 2 to 8 bits. The benchmark included first-order Taylor extrapolation, an adaptive-order predictor, a constant-velocity Kalman filter, and a two-layer long short-term memory (LSTM) network. We used an open-loop protocol in which all predictors received past original samples. This protocol isolates intrinsic prediction performance from recursive reconstruction-error propagation. Saturation rate (SR) was the primary metric, complemented by overflow energy ratio (OER), which weights each event by its squared overflow depth. On a 5,317-sample excerpt from MIT-BIH Arrhythmia Database Record 101, the Kalman predictor performed best at Br=6. It achieved 30.88 dB SNR, 2.16% SR, and 12.93% OER, compared with 28.39 dB, 2.69%, and 25.29% for Taylor extrapolation. The adaptive-order predictor achieved 29.61 dB SNR and 2.44% SR using three registers, two comparators, and no multiplier. The LSTM reached 29.28 dB SNR and did not outperform the model-based predictors on this limited-data benchmark. Under the evaluated excerpt and open-loop protocol, Br=6 provided a favorable balance between reconstruction fidelity and conversion depth. Closed-loop, multi-subject, and hardware validation are required before system-level energy or deployment claims can be made.
评论: 10 pages , 4figures
主题: 信号处理 (eess.SP)
引用方式: arXiv:2608.00992 [eess.SP]
  (或者 arXiv:2608.00992v1 [eess.SP] 对于此版本)
  https://doi.org/10.48550/arXiv.2608.00992

提交历史

来自:Xiyuan Feng
[v1] 2026年8月2日 星期日 04:42:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SP
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-08
切换浏览方式为:
eess

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站