跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

定量生物学 > 定量方法

arXiv:2609.01228 (q-bio)
[提交于 2026年9月1日 (v1),最后修订于 2026年11月23日 (此版本, v5)]

标题:On the interpretation of the kinetics of ligand-receptor binding

作者:David Colquhoun, James P Higham
查看论文《On the interpretation of the kinetics of ligand-receptor binding》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:When the rates of ligand binding are measured by methods such as surface plasmon resonance, it is common practice to use the observed rate constants for the onset and offset of binding to estimate an equilibrium constant for ligand binding. If this agrees with the equilibrium constant found as the EC50 for binding at equilibrium, this is taken as validation of the measured rates. This is correct only when binding produces no conformation change in the receptor, and ligand binding follows a single exponential time course. Here, we investigate a simple 3 state model in which binding is followed by a conformation change in the receptor. Three special cases of this model in which the time course of onset and offset of ligand binding are close to being single exponentials are analysed. These cases are (1) when binding is much faster than the conformation change, (2) when the conformation change is much faster than binding, and (3) when the rates of ligand dissociation and receptor activation are both fast. It is concluded that the measured rates will often yield an estimate of the equilibrium constant for ligand binding that is close to the effective, or macroscopic, equilibrium constant, the EC50 found by measuring binding at equilibrium, which depends on both of the underlying microscopic equilibrium constants describing ligand binding and the conformation change. The exception to this conclusion is the case when binding is much faster than the subsequent conformation change, though the estimate of the equilibrium constant for ligand binding still depends on both of the underlying microscopic equilibrium constants.
评论: 40 pages, 7 in-text figures, electronic supplementary material available: https://doi.org/10.6084/m9.figshare.33406285
主题: 定量方法 (q-bio.QM)
引用方式: arXiv:2609.01228 [q-bio.QM]
  (或者 arXiv:2609.01228v5 [q-bio.QM] 对于此版本)
  https://doi.org/10.48550/arXiv.2609.01228

提交历史

来自:James Higham
[v1] 2026年9月1日 星期二 13:29:15 UTC (1,716 KB)
[v2] 2026年9月2日 星期三 11:49:21 UTC (1,723 KB)
[v3] 2026年9月6日 星期日 15:56:41 UTC (1,633 KB)
[v4] 2026年9月15日 星期二 23:31:48 UTC (1,585 KB)
[v5] 2026年11月23日 星期一 15:55:42 UTC (1,587 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

q-bio.QM
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
q-bio

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站