跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 光学

arXiv:2609.11299 (physics)
[提交于 2026年9月10日]

标题:A Two-Mirror Faceted Projection System for EUV Lithography

作者:Vasiliy A. Es'kin, Egor V. Ivanov, Olga V. Martynova
查看论文《A Two-Mirror Faceted Projection System for EUV Lithography》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:We propose an all-reflective two-mirror projection system for extreme ultraviolet (EUV) lithography operating at exposure wavelengths of $13.5$~nm (Mo/Si) and $11.2$~nm (Ru/Be), delivering a fourfold ($4\times$) demagnification of the periodic mask pattern at a numerical aperture approaching unity ($\mathrm{NA}_{\max} \approx 0.993$). In contrast to conventional EUV projection objectives that incorporate 6--10 aspheric mirrors with an overall optical throughput of less than $15\%$, the proposed design redirects each accepted discrete spatial diffraction order scattered by the mask onto the wafer via a dedicated pair of planar mirror facets. The number of reflections is strictly fixed at two for all accepted orders, retaining $50$--$60\%$ of the power leaving the mask in each accepted order. We derive a spatial geometry providing rigorous optical path length equalization across all diffraction orders, thereby removing order-dependent propagation phase shifts. Individually optimized 30-bilayer Bragg multilayer coatings are designed for each facet using the transfer matrix method combined with global evolutionary optimization algorithms. The architecture is generalized to a three-dimensional vector formulation with a two-dimensionally periodic mask. Utilizing inverse lithography technology, Fourier parameterization, and a differentiable electromagnetic modal waveguide solver, we solve the synthesis problem for binary absorber masks (La absorber on a Ru/Be/Sr multilayer mirror). We demonstrate simulated aerial images of sub-10-nm features on the wafer (isolated peaks with a full width at half maximum (FWHM) of approximately $5.4$~nm and line pairs with a critical dimension of $6$~nm) and find that the two peaks remain resolved for the tested wafer defocus values from $0$ to $5$~nm along the $z$-axis.
主题: 光学 (physics.optics); 机器学习 (cs.LG); 应用物理 (physics.app-ph); 经典物理 (physics.class-ph); 计算物理 (physics.comp-ph)
引用方式: arXiv:2609.11299 [physics.optics]
  (或者 arXiv:2609.11299v1 [physics.optics] 对于此版本)
  https://doi.org/10.48550/arXiv.2609.11299

提交历史

来自:Vasiliy A. Es'kin
[v1] 2026年9月10日 星期四 09:28:02 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.optics
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-09
切换浏览方式为:
physics
cs.LG
physics.app-ph
physics.class-ph
physics.comp-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站