标题:Quiet, rapid 3D multiparametric mapping using magnetization-prepared zero echo time MRI

作者:Alireza Samadifardheris, Shishuai Wang, Ana Beatriz Solana, Jose de Arcos, Noemi Sgambelluri, Emil Langensee Ljungberg, Sagar Mandava, Mika Vogel, Steven C. R. Williams, Stefan Klein, Juan Antonio Hernandez-Tamames, Dirk H. J. Poot, Florian Wiesinger
查看论文《Quiet, rapid 3D multiparametric mapping using magnetization-prepared zero echo time MRI》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: To introduce and evaluate MuPa-ZTE, a quiet, rapid 3D framework combining native and magnetization-prepared zero echo time (ZTE) acquisitions for multiparametric mapping. Methods: MuPa-ZTE combines steady-state native ZTE with transient-state magnetization-prepared ZTE. Two implementations were evaluated: T2T1-ZTE for apparent proton density, T1, and T2 mapping, and T1-ZTE for apparent proton density and T1 mapping. Both were assessed in an ISMRM/NIST system phantom and two healthy volunteers; T2T1-ZTE was also demonstrated in a patient with brain metastases. The 10-minute phantom and 4.5-minute in vivo acquisitions were retrospectively truncated to 3, 2, and 1 minute and reconstructed with and without deep learning-based denoising. Evaluations included phantom agreement, precision, short-term repeatability, apparent SNR, edge sharpness, and consistency with full-duration in vivo maps. Results: T1 estimates remained close to nominal phantom values across implementations, durations, and reconstructions. T2 accuracy was maintained down to 2 minutes over the brain-relevant range, with limited sensitivity to longer T2 values. Denoising generally reduced variability and improved short-term repeatability. In vivo, 1.1-mm isotropic whole-brain maps were obtained in 4.5 minutes; denoising increased apparent SNR while preserving edge sharpness and yielded promising image quality after retrospective truncation to 2 minutes. Conclusion: MuPa-ZTE enables quiet, isotropic 3D multiparametric mapping within 4.5 minutes, supporting robust T1 mapping and T2 mapping over a brain-relevant range, with promising acceleration toward 2 minutes using deep learning-based denoising.
评论: Alireza Samadifardheris and Shishuai Wang contributed equally to this work.Submitted to Magnetic Resonance in Medicine
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2610.01330 [physics.med-ph]
  (或者 arXiv:2610.01330v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2610.01330

提交历史

来自:Shishuai Wang
[v1] 2026年10月1日 星期四 08:59:24 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-10
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站