跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 计算物理

arXiv:2610.03297 (physics)
[提交于 2026年10月2日]

标题:Experimental Bench Validation of a Computational Fluid-Structure Interaction Model of Transcatheter Aortic Valve Dynamics

作者:Jae H. Lee, Paul Ahern, Anh D. Nguyen, Masod Sadipour, Robert Hunt, Wyatt Kmetz, Boyce E. Griffith
查看论文《Experimental Bench Validation of a Computational Fluid-Structure Interaction Model of Transcatheter Aortic Valve Dynamics》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: This study extends our fluid-structure interaction (FSI) framework for surgical bioprosthetic heart valves in an experimental pulse duplicator to a transcatheter aortic valve replacement (TAVR) device. We assess hemodynamic and leaflet kinematic agreement across pulse rates and the transferability of calibrated boundary-model parameters. Methods: We compared simulated and experimental pressure, volumetric flow rate, projected dynamic valve area (PDVA), and leaflet kinematics at 60, 70, and 80 beats per minute (bpm). Reduced-order boundary-model parameters were calibrated using only data acquired at 70 bpm and were subsequently held fixed. At each pulse rate, a condition-specific pump-pressure waveform was constructed from the measured upstream pressure and flow rate. The 60 and 80 bpm cases therefore evaluate parameter transfer under measurement-informed upstream forcing. Results: Across the three conditions, normalized root-mean-square errors are 2.88-3.08% for aortic flow rate, 7.64-8.07% for upstream ventricular pressure, 3.50-6.21% for downstream aortic pressure, and 3.07-4.70% for PDVA. The simulations reproduce the principal pressure, flow, valve-opening, and valve-closure features. The downstream aortic pressure and PDVA measurements at 60 and 80 bpm were not used to construct the upstream forcing or recalibrate the model parameters and therefore provide the principal out-of-calibration validation evidence. Conclusion: The results provide conditional experimental bench validation evidence for downstream hemodynamics and valve dynamics under measurement-informed upstream forcing and support boundary-parameter transfer across pulse rates without recalibration. This work advances an experimentally supported, high-fidelity FSI framework for evaluating TAVR device performance.
主题: 计算物理 (physics.comp-ph); 流体动力学 (physics.flu-dyn)
引用方式: arXiv:2610.03297 [physics.comp-ph]
  (或者 arXiv:2610.03297v1 [physics.comp-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2610.03297

提交历史

来自:Jae Lee
[v1] 2026年10月2日 星期五 13:38:20 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.comp-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-10
切换浏览方式为:
physics
physics.flu-dyn

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站