标题:Optimization of curved vortex generator geometry for enhanced thermal performance in water-to-air finned-tube heat exchanger

作者:Josip Batista, Anica Trp, Kristian Lenić, Mateo Kirinčić
查看论文《Optimization of curved vortex generator geometry for enhanced thermal performance in water-to-air finned-tube heat exchanger》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:In the study, the geometry of curved rectangular vortex generators (RVG) has been optimized to enhance heat transfer and overall performance of the analyzed water-to-air finned-tube heat exchanger (FTHE). The developed and validated conjugate numerical model includes a small section of the full-scale heat exchanger representing the computational domain, with fully developed velocity and temperature profiles specified at the inlet boundaries of the water. Four influential geometry parameters of the vortex generator were selected for the optimization; attack angle, curvature angle, axial position in the streamwise direction and height. The optimization process has been performed according to two criteria: maximization of heat transfer solely and maximization of heat transfer while considering the influence of pressure drop. Accordingly, one objective function related to the Colburn factor (j) and two objective functions combining the Colburn factor and the friction factor (f) were defined. The regression analysis has been used and the Central composite design of experiment was selected in order to obtain non-linear regression polynomial functions which were integrated into the investigated objectives. The optimization procedure has been performed using the genetic algorithm. Optimized configurations performance improvement was evaluated through comparison with the performance of the reference FTHE with plain fins. For the RVG configuration optimized according to the objective of maximizing heat transfer, the Colburn factor was enhanced by 53.1%. Optimizing the RVG configuration to maximize heat transfer while accounting for the influence of pressure drop resulted in an enhancement of the FTHE area goodness factor by 14.4% for one set of geometry parameters, and an enhancement of volume goodness factor by 26.5% for another.
主题: 经典物理 (physics.class-ph); 计算物理 (physics.comp-ph); 流体动力学 (physics.flu-dyn)
引用方式: arXiv:2610.39780 [physics.class-ph]
  (或者 arXiv:2610.39780v1 [physics.class-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2610.39780
期刊参考: International Communications in Heat and Mass Transfer 178 (2026) 111637
相关 DOI: https://doi.org/10.1016/j.icheatmasstransfer.2026.111637

提交历史

来自:Anica Trp
[v1] 2026年10月29日 星期四 10:30:37 UTC (2,694 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.class-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-10
切换浏览方式为:
physics
physics.comp-ph
physics.flu-dyn

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站