标题:Cross-Device Transfer of a Hospital-Trained Fetal Head Circumference Model to a Low-Cost Handheld Ultrasound Probe

作者:Patrick Gao, Lara Hart, Ken Sullivan
查看论文《Cross-Device Transfer of a Hospital-Trained Fetal Head Circumference Model to a Low-Cost Handheld Ultrasound Probe》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Automated fetal head circumference (HC) measurement reaches near-expert accuracy on the HC18 benchmark, but published models are trained and evaluated on hospital-grade equipment. We quantify what happens when such a model is carried to a low-cost handheld probe. A lightweight segmentation network (CSM, 0.13M parameters) was trained on HC18 across five independent runs and applied without modification to images from a $1,350 handheld probe (SonoQue C3), acquired at the same visit as the reference hospital scan in 18 patients. In-domain accuracy was 2.34 +/- 0.43 mm; on handheld images the same model gave 16.12 mm against the hospital record, a 6.9-fold degradation. Input preprocessing, a choice rarely reported, accounted for about a third of that gap: direct resizing gave 49.45 mm against 16.12 mm for an aspect-preserving pipeline. A leave-one-out data-efficiency curve showed that fine-tuning on two images significantly worsened accuracy, and that from four images upward error fell by 0.75 mm per doubling of the local dataset (p = 0.0045), although no training-set size up to 27 images significantly improved on the unmodified model. Much of the residual gap belongs to the reference rather than the model: scored against a manual tracing of the same image the model was already within 10.48 mm, and its disagreement with sonographer calipers on the same frame was a near-constant offset, negative in 10 of 10 cases. A single calibration constant estimated leave-one-out reduced that disagreement from 8.12 mm to 3.49 mm, reaching the intraobserver reproducibility reported for experienced sonographers, but did not improve agreement with the hospital record. Cross-device evaluations should therefore report the input preprocessing used and characterise the precision of their reference standard.
评论: 24 pages, 5 figures, 4 tables
主题: 图像与视频处理 (eess.IV)
引用方式: arXiv:2610.40710 [eess.IV]
  (或者 arXiv:2610.40710v1 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.2610.40710

提交历史

来自:Patrick Gao
[v1] 2026年10月28日 星期三 23:56:46 UTC (1,281 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
eess

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站