跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 仪器与探测器

arXiv:2610.41894 (physics)
[提交于 2026年10月30日]

标题:Calorimetry as inference: the information content of particle showers and the limits of energy measurement

作者:Wonyong Chung
查看论文《Calorimetry as inference: the information content of particle showers and the limits of energy measurement》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:A calorimeter does not measure the energy of a particle, it infers it from the record the absorption process leaves behind. Energy conservation writes every event as an accounting ledger, E = E_dis + E_B + E_esc + E_nu, of which only the dissipated component contributes to signal, so resolution is limited by how well the record of the dissipation constrains the missing entries. We formalize this: records form a lattice on which information is monotone; thinning a Poisson record scales Fisher information exactly by the retention; clustered records read out as sums cost the 1/(1+cv^2); and the quadrature budget a/sqrt(E) (+) b is the floor of every summed readout. The "ultimate limits" of hadronic calorimetry are identified as the first rung of a ladder, the residual spread of the invisible energy around a single correlated observable. We measure the ladder above that rung on Geant4 truth records of hadronic showers in copper, from the dissipated-energy sum to time-, position- and multiplicity-resolved records, with estimators validated on exactly solvable toy models. The achieved full-record value, model-conditional, is about 5.5%/sqrt(E) (+) 0.3% over 20-100 GeV, a factor 1.7-1.9 below the canonical one-functional construction on the same events (1.29% vs. 2.14% at 20 GeV). Under retrained high-precision neutron transport it moves from 1.29% to 1.30%, the dissipated-energy sum by 7%, and the gain from time structure becomes 0.17% in place of 0.28%. Dual-readout supplies the largest share of the information. Shower shape is next, almost entirely longitudinal, saturating at about one interaction length. Time structure adds nearly as much with or without shower shape, and stopped-muon neutrino losses set an estimated floor of 0.99% at 20 GeV. Every readout dimension has a measured information exchange rate, separating what new hardware can buy from what better algorithms can recover.
评论: 17 pages, 4 figures
主题: 仪器与探测器 (physics.ins-det); 高能物理 - 实验 (hep-ex)
引用方式: arXiv:2610.41894 [physics.ins-det]
  (或者 arXiv:2610.41894v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.2610.41894

提交历史

来自:Wonyong Chung
[v1] 2026年10月30日 星期五 15:35:03 UTC (274 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics
hep-ex

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站