标题:ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals

作者:Shovito Barua Soumma, Asiful Arefeen, Hassan Ghasemzadeh
查看论文《ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Accurate heart rate (HR) and interbeat interval (IBI) estimation from wearable electrocardiogram (ECG) is essential for continuous physiological monitoring, but motion artifacts can create false QRS-like peaks and obscure true R-peaks. Conventional detectors and local interval-repair rules process detections independently and may become unreliable when several consecutive beats are corrupted. We present ARTA (Artifact-Robust Temporal Alignment), a graph-based combinatorial framework that estimates the heartbeat sequence through constrained temporal optimization. ARTA combines candidates from multiple ECG detectors, represents them as nodes in a directed acyclic graph and connects candidates through physiologically plausible RR intervals. Candidate confidence uses detector agreement and local ECG quality, while history-dependent transition costs capture recent IBI consistency and a soft heart-rate prior. Beam-search dynamic programming selects a coherent low-cost path across the recording, suppressing false detections and recovering missed beats when plausible auxiliary candidates are available. On the IEEE Signal Processing Cup exercise dataset with electrode-motion artifacts from -2 to 12 dB, ARTA achieved an HR mean absolute error of 1.79 beats per minute, 54% lower than the strongest single-detector baseline, with 92.38% of windows within +/-5 beats per minute, an R-peak F1 score of 0.95, and an IBI mean absolute error of 6.52 ms. Cross-dataset evaluation on the European ST-T Database further assessed transfer to long clinical ambulatory recordings and a label-free reliability analysis examined conditional performance without using reference annotations for segment selection. ARTA is single-channel, training-free, interpretable and computationally lightweight, operating approximately 27 times faster than real time with peak memory below 2.1 MB in a single-thread CPU simulation.
评论: Under Review
主题: 信号处理 (eess.SP); 计算与语言 (cs.CL); 数学软件 (cs.MS)
引用方式: arXiv:2611.00011 [eess.SP]
  (或者 arXiv:2611.00011v1 [eess.SP] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.00011

提交历史

来自:Shovito Barua Soumma
[v1] 2026年9月15日 星期二 20:15:14 UTC (3,027 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SP
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-09
切换浏览方式为:
eess
cs.CL
cs.MS

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站