跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

计算机科学 > 机器学习

arXiv:2611.00428 (cs)
[提交于 2026年10月30日]

标题:Do Multimodal Models Decide Consistently on Equivalent Optical Spectra?

作者:Ziyuan Wang, Genliang Zhu, Xiaobo Chen
查看论文《Do Multimodal Models Decide Consistently on Equivalent Optical Spectra?》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:A spectrum can be given to a model as a table in nanometers or as a plot in photon energy, and the decision should not depend on which one it sees. When the data needed for an answer are missing, the model should say so. We test representation invariance and abstention on measured optical spectra of silicon metasurfaces (MOCLIP) and gold nanoparticles, with labels computed from the data. Each spectrum is shown as four tables (nm, $\mu$m, scientific notation, eV) and two plots (nm, eV), and partial spectra remove data inside or outside the queried range. We evaluate the decision models d3-nano and Jev 1.13, three GPT-6 Luna configurations and the Qwen3.5-2B base model. Changing only the representation moves accuracy by up to 41 percentage points within one model, mostly on photon-energy tables and plots. With the same evidence, asking in photon energy instead of wavelength helps some model-view pairs by 16-50 points and hurts others by up to 25. When the relevant extremum is removed, unadapted models rarely answer "undetermined". LoRA fine-tuning of d3-nano improves comparisons on the trained table formats, but much of its gain on unanswerable questions comes from a shortcut: it abstains whenever the input is truncated. Training with answerable truncations avoids the shortcut in all six seeds, with a 90-100 point gap between abstention after inside and outside cuts on held-out structures; with the same amount of extra original-task data, five of six seeds keep the shortcut. On gold spectra the two training sets perform similarly. Multimodal language models used for scientific decisions should be tested on equivalent representations and on missing evidence, not only on average accuracy. We release the tasks, per-response results and analysis code.
评论: 20 pages, 4 figures, 11 tables. Code and data: https://github.com/zwang-devv/spectra-decision-audit
主题: 机器学习 (cs.LG); 计算与语言 (cs.CL); 光学 (physics.optics)
引用方式: arXiv:2611.00428 [cs.LG]
  (或者 arXiv:2611.00428v1 [cs.LG] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.00428

提交历史

来自:Ziyuan Wang
[v1] 2026年10月30日 星期五 22:21:38 UTC (113 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.LG
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
cs
cs.CL
physics.optics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站